MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2025.08.028

Медицинская библиотека · JACC. Clinical electrophysiology · 2025

Ultrasound-Based Renal Sympathetic Denervation as Adjunctive Upstream Therapy During Atrial Fibrillation Ablation: The ULTRA-HFIB Pilot.

Whang William, Nair Devi, Bhardwaj Rahul, Lahiri Marc, Sharma Dinesh, Kobayashi Taisei, Doshi Shephal K, Natale Andrea, Moskowitz Craig, Mansour Moussa, Swarup Vijay, Turagam Mohit K, Dukkipati Srinivas, Hyman Matthew C, Mohanty Sanghamitra, Lam Jeff, Gurol Ugur, Silva Carla Perdomo, Reddy Vivek Y

СтатьяРандомизированное исследованиеМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

During atrial fibrillation (AF) ablation, adjunctive renal denervation (RDN), by virtue of its effect on the sympathetic/renin-angiotensin-aldosterone axis, has improved AF control. However, patients in these studies mostly had uncontrolled hypertension.

OBJECTIVES

The aim of this study was to assess the effect of RDN using an ultrasound catheter to improve rhythm outcomes in patients with hypertension (including controlled hypertension) undergoing AF ablation.

METHODS

This investigator-initiated, sham-controlled, single-blind randomized controlled U.S. Food and Drug Administration trial included first-ever paroxysmal or persistent AF ablation patients with histories of hypertension receiving ≥1 antihypertensive medication. Post-AF ablation randomization was 1:1 to RDN using a circumferential ultrasound system or sham control; patients with ineligible renal arterial anatomy were screen failures. The primary endpoint was 12-month freedom from AF or atrial flutter (AFL) (≥30 seconds) off antiarrhythmic medications after 90-day blanking.

RESULTS

At 9 centers, 107 patients were randomized; excluding 7 screen failures, the 100-patient cohort (mean age 66 ± 9 years, 35% women, paroxysmal and persistent AF in 86% and 14%) underwent radiofrequency ablation (55%) or cryoablation (45%) for AF. The 1-year Kaplan-Meier estimates for freedom from AF or AFL were 49% for sham vs 67% for RDN (log-rank P = 0.17). In a Cox analysis adjusted for age, sex, and persistent AF, the HR for recurrent AF or AFL with RDN was 0.65 (95% CI: 0.32-1.31; P = 0.23). There were no RDN-related adverse events.

CONCLUSIONS

In this AF ablation cohort, adjunctive RDN was safe and reduced AF and AFL recurrence by 35%, an effect not reaching statistical significance in this pilot trial. A fully powered randomized trial is warranted to define the impact of RDN among patients planned for AF ablation.

Для цитирования: Whang William, Nair Devi, Bhardwaj Rahul, Lahiri Marc, Sharma Dinesh, Kobayashi Taisei, Doshi Shephal K, Natale Andrea, Moskowitz Craig, Mansour Moussa, Swarup Vijay, Turagam Mohit K, Dukkipati Srinivas, Hyman Matthew C, Mohanty Sanghamitra, Lam Jeff, Gurol Ugur, Silva Carla Perdomo, Reddy Vivek Y. Ultrasound-Based Renal Sympathetic Denervation as Adjunctive Upstream Therapy During Atrial Fibrillation Ablation: The ULTRA-HFIB Pilot.. JACC. Clinical electrophysiology. 2025. DOI: 10.1016/j.jacep.2025.08.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.