Reproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI.

Won So Yeon, Lee Kijeong, Shin Ilah, Choi Hyun Seok, Choi Jai Ho, Kim Bum-Soo, Shin Yong Sam

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

T1-weighted (T1W) magnetic resonance imaging (MRI) using the delay alternating with nutation for excitation-sampling perfection with application-optimized contrasts using different flip angle evolution (DANTE-SPACE) is the preferred imaging technique for evaluation of the vessel wall.

PURPOSE: To evaluate the intra- and inter-rater reproducibility of carotid wall segmentation on T1W DANTE-SPACE in patients with symptomatic (acute stroke or transient ischemic attack) internal carotid artery (ICA) stenosis.

MATERIAL AND

METHODS

This prospective study included 25 patients with acute (≤3 months) stroke or transient ischemic attack and 50%-99% stenosis of the ICA. All patients underwent 3.0-T high-resolution carotid MRI. Two radiologists independently performed the manual segmentation of the vessel wall and inner lumen of the bilateral carotid artery on DANTE-SPACE. The intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and Hausdorff distance (HD) were calculated.

RESULTS

The ICCs for intra-rater reproducibility of carotid wall volume, inner lumen volume, and normalized wall index were 0.965, 0.990, and 0.962, respectively. The ICCs for inter-rater reproducibility of carotid wall volume, inner lumen, and normalized wall index were 0.856, 0.981, and 0.904. DSC and HD for intra- and inter-rater reproducibility of carotid wall segmentation were as follows: 0.873 and 0.809 (DSC); and 0.079 and 0.118 (HD), respectively. For evaluation of reproducibility only in the carotid artery with symptomatic stenosis, the ICCs for intra- and inter-rater reproducibility indicated all perfect agreement.

CONCLUSION

T1W DANTE-SPACE is a reproducible sequence for evaluation of the carotid wall using carotid MRI in patients with symptomatic ICA stenosis.

Для цитирования: Won So Yeon, Lee Kijeong, Shin Ilah, Choi Hyun Seok, Choi Jai Ho, Kim Bum-Soo, Shin Yong Sam. Reproducibility for carotid wall segmentation using T1-weighted DANTE-SPACE sequence on high-resolution 3-T carotid MRI.. Acta radiologica (Stockholm, Sweden : 1987). 2024. DOI: 10.1177/02841851241268467.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.