MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bios.2022.114222

Медицинская библиотека · Biosensors & bioelectronics · 2022

Performance of electrochemical immunoassays for clinical diagnostics of SARS-CoV-2 based on selective nucleocapsid N protein detection: Boron-doped diamond, gold and glassy carbon evaluation.

Białobrzeska Wioleta, Ficek Mateusz, Dec Bartłomiej, Osella Silvio, Trzaskowski Bartosz, Jaramillo-Botero Andres, Pierpaoli Mattia, Rycewicz Michał, Dashkevich Yanina, Łęga Tomasz, Malinowska Natalia, Cebula Zofia, Bigus Daniel, Firganek Daniel, Bięga Ewelina, Dziąbowska Karolina, Brodowski Mateusz, Kowalski Marcin, Panasiuk Mirosława, Gromadzka Beata, Żołędowska Sabina, Nidzworski Dawid, Pyrć Krzysztof, Goddard William A, Bogdanowicz Robert

СтатьяПеревод пока не подготовлен

Аннотация

The 21st century has already brought us a plethora of new threats related to viruses that emerge in humans after zoonotic transmission or drastically change their geographic distribution or prevalence. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was first spotted at the end of 2019 to rapidly spread in southwest Asia and later cause a global pandemic, which paralyzes the world since then. We have designed novel immunosensors targeting conserved protein sequences of the N protein of SARS-CoV-2 based on lab-produced and purified anti-SARS-CoV-2 nucleocapsid antibodies that are densely grafted onto various surfaces (diamond/gold/glassy carbon). Titration of antibodies shows very strong reactions up to 1:72 900 dilution. Next, we showed the mechanism of interactions of our immunoassay with nucleocapsid N protein revealing molecular recognition by impedimetric measurements supported by hybrid modeling results with both density functional theory and molecular dynamics methods. Biosensors allowed for a fast (in less than 10 min) detection of SARS-CoV-2 virus with a limit of detection from 0.227 ng/ml through 0.334 ng/ml to 0.362 ng/ml for glassy carbon, boron-doped diamond, and gold surfaces, respectively. For all tested surfaces, we obtained a wide linear range of concentrations from 4.4 ng/ml to 4.4 pg/ml. Furthermore, our sensor leads to a highly specific response to SARS-CoV-2 clinical samples versus other upper respiratory tract viruses such as influenza, respiratory syncytial virus, or Epstein-Barr virus. All clinical samples were tested simultaneously on biosensors and real-time polymerase chain reactions.

Для цитирования: Białobrzeska Wioleta, Ficek Mateusz, Dec Bartłomiej, Osella Silvio, Trzaskowski Bartosz, Jaramillo-Botero Andres, Pierpaoli Mattia, Rycewicz Michał, Dashkevich Yanina, Łęga Tomasz, Malinowska Natalia, Cebula Zofia, Bigus Daniel, Firganek Daniel, Bięga Ewelina, Dziąbowska Karolina, Brodowski Mateusz, Kowalski Marcin, Panasiuk Mirosława, Gromadzka Beata, Żołędowska Sabina, Nidzworski Dawid, Pyrć Krzysztof, Goddard William A, Bogdanowicz Robert. Performance of electrochemical immunoassays for clinical diagnostics of SARS-CoV-2 based on selective nucleocapsid N protein detection: Boron-doped diamond, gold and glassy carbon evaluation.. Biosensors & bioelectronics. 2022. DOI: 10.1016/j.bios.2022.114222.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.