Comparing HeartModelAI and cardiac magnetic resonance imaging for left ventricular volume and function evaluation in patients with dilated cardiomyopathy.

Sheikh Mahboobeh, Fallah Sahar Asl, Moradi Muhammadhosein, Jalali Arash, Vakili-Basir Ahmad, Sahebjam Mohammad, Ashraf Haleh, Zoroufian Arezou

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Integration of artificial intelligence enhances precision, yielding dependable evaluations of left ventricular volumes and ejection fraction despite image quality variations. Commercial software like HeartModelAI provides fully automated 3DE quantification, simplifying the measurement of left chamber volumes and ejection fraction. In this manuscript, we present a cross-sectional study to assess and compare the diagnostic accuracy of automated 3D echocardiography (HeartModelAI) to the standard Cardiac Magnetic Resonance Imaging in patients with dilated cardiomyopathy.

METHODS

In this cross-sectional study, 30 patients with dilated cardiomyopathy referring to the Tehran Heart Center with cardiac magnetic resonance imaging and comprehensive 3D transthoracic echocardiography within 24 h were included. All 3D volume analysis was performed with fully automated quantification software (HeartModelAI) using 3D images of 2,3, and 4-chamber views at the end of systole and diastole.

RESULTS

Excellent Inter- and Intra-observer correlation coefficient was reported for HeartModelAI software for all indexes. HeartModelAI displayed a remarkable correlation with cardiac magnetic resonance for left ventricular end-systolic volume index (r = 0.918 and r = 0.911); nevertheless, it underestimated left ventricular end-systolic volume index and left ventricular end-diastolic volume index. Conversely, ejection fraction, stroke volume, and left ventricular mass were overestimated. It was found that manual contour correction can enhance the accuracy of automated model estimations, particularly concerning EF in participants needing correction.

CONCLUSION

HeartModelAI software emerges as a rapid and viable imaging approach for evaluating the left ventricle's structure and function. In our study, LV volumes assessed by HeartModelAI demonstrated strong correlations with cardiac magnetic resonance imaging.

Для цитирования: Sheikh Mahboobeh, Fallah Sahar Asl, Moradi Muhammadhosein, Jalali Arash, Vakili-Basir Ahmad, Sahebjam Mohammad, Ashraf Haleh, Zoroufian Arezou. Comparing HeartModelAI and cardiac magnetic resonance imaging for left ventricular volume and function evaluation in patients with dilated cardiomyopathy.. BMC cardiovascular disorders. 2024. DOI: 10.1186/s12872-024-04355-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.