MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/bioengineering11101012

Медицинская библиотека · Bioengineering (Basel, Switzerland) · 2024

Comparison of Electrocardiogram between Dilated Cardiomyopathy and Ischemic Cardiomyopathy Based on Empirical Mode Decomposition and Variational Mode Decomposition.

Han Yuduan, Ding Chonglong, Yang Shuo, Ge Yingfeng, Yin Jianan, Zhao Yunyue, Zhang Jinxin

СтатьяПеревод пока не подготовлен

Аннотация

The clinical manifestations of ischemic cardiomyopathy (ICM) bear resemblance to dilated cardiomyopathy (DCM), yet their treatments and prognoses are quite different. Early differentiation between these conditions yields positive outcomes, but the gold standard (coronary angiography) is invasive. The potential use of ECG signals based on variational mode decomposition (VMD) as an alternative remains underexplored. An ECG dataset containing 87 subjects (44 DCM, 43 ICM) is pre-processed for denoising and heartbeat division. Firstly, the ECG signal is processed by empirical mode decomposition (EMD) and VMD. And then, five modes are determined by correlation analysis. Secondly, bispectral analysis is conducted on these modes, extracting corresponding bispectral and nonlinear features. Finally, the features are processed using five machine learning classification models, and a comparative assessment of their classification efficacy is facilitated. The results show that the technique proposed provides a better categorization for DCM and ICM using ECG signals compared to previous approaches, with a highest classification accuracy of 98.30%. Moreover, VMD consistently outperforms EMD under diverse conditions such as different modes, leads, and classifiers. The superiority of VMD on ECG analysis is verified.

Для цитирования: Han Yuduan, Ding Chonglong, Yang Shuo, Ge Yingfeng, Yin Jianan, Zhao Yunyue, Zhang Jinxin. Comparison of Electrocardiogram between Dilated Cardiomyopathy and Ischemic Cardiomyopathy Based on Empirical Mode Decomposition and Variational Mode Decomposition.. Bioengineering (Basel, Switzerland). 2024. DOI: 10.3390/bioengineering11101012.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.