BACKGROUND

Fractures of the pelvis and acetabulum are relatively rare, with a reported incidence of 3% to 8% of all adult fractures, but occur in approximately 20% of all polytrauma cases. They have high associated morbidity (40% to 50%) and mortality (5% to 30%). It is recommended that an external compression splint be applied in the presence of a suspected pelvic fracture before transfer and definitive investigation and management.

CASE REPORT: Two cases are presented in which these recommendations were met and the patients underwent computed tomography (CT) scanning upon arrival to the emergency department at a major trauma center with the pelvic binder in situ. In both these cases, CT scanning failed to identify a significant pelvic injury, which was concealed by the pelvic external compression belt. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: When there is high clinical indication of pelvic injury, whether related to mechanism of injury or clinical findings, despite a CT scan where no bony injury is identified, obtaining plain pelvic x-ray studies out of the pelvic compression device to avoid overlooking or neglecting a significant pelvic injury would be prudent.

Для цитирования: Clements Jenny, Jeavons Richard, White Craig, McMurtry Ian. The Concealment of Significant Pelvic Injuries on Computed Tomography Evaluation by Pelvic Compression Devices.. The Journal of emergency medicine. 2015. DOI: 10.1016/j.jemermed.2015.03.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.