When does hip fracture surgery fail?

Tsang S T J, Aitken S A, Golay S K, Silverwood R K, Biant L C

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Hip fractures remain the most common orthopaedic injury requiring hospital admission. Failed surgery for any cause carries a higher morbidity, mortality, and healthcare-related cost. The aims of this study were to determine risk factors for surgical complications of hip fracture surgery, when they occurred and their effect on mortality.

PATIENTS AND

METHODS

From a prospectively collected consecutive database of 795 hip fractures admitted between July 2007 and June 2008, all surgical and non-surgical complications were identified as well as re-operation for any cause and mortality in the 4 years since surgery.

RESULTS

Fifty-five (6.9%) patients were found to have developed a surgical complication requiring further intervention. Risk factors included younger age, smoking and cannulated screw fixation. Cannulated screw fixation was associated with a 30.9% rate of re-operation. Post-operative medical complication occurred in 21.8%. It was associated with a 78.5% mortality at 4 years with a median time to mortality of 58 days (95% CI 0-120 days).

CONCLUSIONS

Mechanical failure was the most common reason for cannulated screw re-operation. Hip hemiarthroplasty most commonly failed by infection. Inter-trochanteric and sub-trochanteric fracture fixation had very low failure rates. Post-operative medical complications, but not surgical complications, were associated with a higher mortality rate.

Для цитирования: Tsang S T J, Aitken S A, Golay S K, Silverwood R K, Biant L C. When does hip fracture surgery fail?. Injury. 2014. DOI: 10.1016/j.injury.2014.03.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.