MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-012-1507-6

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2012

Cervical lateral mass screw fixation without fluoroscopic control: analysis of risk factors for complications associated with screw insertion.

Inoue Shinichi, Moriyama Tokuhide, Tachibana Toshiya, Okada Fumiaki, Maruo Keishi, Horinouchi Yutaka, Yoshiya Shinichi

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To examine the outcome of cervical lateral mass screw fixation focusing on analysis of the risk factors for screw-related complications.

METHODS

Ninety-four patients who underwent posterior cervical fixation with a total of 457 lateral mass screws were included in the study. The lateral mass screws were placed using a modified Magerl method. Computed tomographic (CT) images were taken in the early postoperative period in all patients, and the screw trajectory angle was measured on both axial and sagittal plane images.

RESULTS

In the postoperative CT analysis for the screw trajectory, 56.5 % of the screws were directed within the acceptable range (within 21-40° on both axial and sagittal planes). As intraoperative screw-associated complications, 9.6 % of the screws were found to contact with or breach the vertebral artery foramen. In this group, the screw trajectory angle on axial plane was significantly lower than in the group without contact. Facet violation was observed in 13 screws (2.8 %). This complication was associated with a significantly lower trajectory angles in the sagittal plane, predominantly at C6 level (69.2 %). In the patient chart review, no serious neurovascular injuries were documented.

CONCLUSIONS

In the analysis of potential risk factors for violation of the VA foramen as well as FV during screw insertion, the former incidence was significantly related to the screw trajectory angle (lack of lateral angulation) in the axial plane, while the latter incidence was related to a poor screw trajectory angle in the sagittal plane.

Для цитирования: Inoue Shinichi, Moriyama Tokuhide, Tachibana Toshiya, Okada Fumiaki, Maruo Keishi, Horinouchi Yutaka, Yoshiya Shinichi. Cervical lateral mass screw fixation without fluoroscopic control: analysis of risk factors for complications associated with screw insertion.. Archives of orthopaedic and trauma surgery. 2012. DOI: 10.1007/s00402-012-1507-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.