DOI 10.1016/j.arthro.2011.06.021
Poly-L/D-lactic acid anchors are associated with reoperation and failure of SLAP repairs.
Аннотация
PURPOSE: This study investigates factors associated with failure and reoperation after glenoid labrum repair.
METHODS
We studied a nonconcurrent cohort of consecutive patients undergoing arthroscopic superior labrum repair at a single institution by 2 fellowship-trained surgeons over a 10-year period.
RESULTS
There were 348 patients included in this study with a mean age of 33.4 years (95% confidence interval [CI], 32.1 to 35.9) and a mean clinical follow-up of 12.3 months (95% CI, 10.9 to 13.8). The overall reoperation rate was 6.3%, with a revision labrum repair rate of 4.3%. Subsequent surgery and failure after arthroscopic labrum repair were significantly correlated with Workers' Compensation claims (odds ratio [OR], 4.6; P < .001; 95% CI, 1.8 to 11.7), the use of tobacco (OR, 12.0; P = .03; 95% CI, 1.2 to 114.9), and the use of absorbable poly-L/D-lactic acid (PLDLA) anchors (100% correlation, P < .001). The OR for having repeat surgery was 12.7 (95% CI, 4.9 to 32.9; P < .001) with poly-96L/4D-lactic acid (Mini-Revo; Linvatec, Largo, FL) and also increased with the use of poly-70L/30D-lactic acid (Bio-Fastak and Bio-Suturetak; Arthrex, Naples, FL) anchor material (P = .04) after removal of the patients exposed to poly-96L/4D-lactic acid anchors. The rates of repeat surgery with PLDLA anchors from Linvatec and PLDLA anchors from Arthrex were 24% and 4%, respectively. None of the patients treated with nonabsorbable suture anchors (polyether ether ketone or metallic) returned to the operating room (P < .001). After we controlled for associated factors in a multivariate analysis, the use of absorbable anchors, in particular poly-96L/4D-lactic acid anchors (OR, 14.7; P < .001), and having a work-related injury (OR, 8.1; P < .001) remained independent factors associated with both repeat surgery and revision superior labrum repair.
CONCLUSIONS
Bioabsorbable PLDLA anchor material led to significantly more SLAP repair failures and reoperations compared with nonabsorbable suture anchors. Our recommendation is that glenoid labrum repairs be performed with nondegradable material and, specifically, that the use of anchors composed of PLDLA material should be avoided.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.