MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/01477447-20100329-06

Медицинская библиотека · Orthopedics · 2010

Efficacy of a norvancomycin-loaded, PDLLA-coated plate in preventing early infection of rabbit tibia fracture.

Fei Jun, Yu Hong-jun, Pan Chang-jiang, Zhao Chang-hong, Zhou Yong-gang, Wang Yan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Despite improvements in surgical techniques and implant designs in orthopedic surgery, implantation-associated infections are still a challenging problem for surgeons. The goal of this study was to evaluate the efficacy of a norvancomycin-loaded, PDLLA-coated stainless steel plate vs an uncoated stainless steel plate in a rabbit model (n=50). The norvancomycin was delivered from a biodegradable poly(D,L-lactide) (PDLLA) coating of a stainless steel plate. Intraoperatively, rabbit tibia fractures were contaminated with Staphylococcus aureus (10(5) colony forming units) after plate implantation. The implants were either uncoated or coated with PDLLA and norvancomycin. In vivo drug release profiles showed that the norvancomycin release rate was decreased by increasing the time. The norvancomycin concentration in the tissue around the plate was higher than the minimum inhibitory concentration on the 14th day after implantation surgery. The animals were followed up for 28 days. Radiographic examinations were performed, and C-reactive protein and erythrocyte sedimentation rate were determined. Infection was evaluated by histological, microbiological, and radiological analysis. Eight of 25 rabbits (32%) implanted with the norvancomycin-loaded, PDLLA-coated plates were infected. Twenty-three of 25 rabbits (92%) implanted with the uncoated plates were infected (P<.05). The norvancomycin-loaded, PDLLA-coated plate may be used to treat open fractures to reduce the incidence of early infection.

Для цитирования: Fei Jun, Yu Hong-jun, Pan Chang-jiang, Zhao Chang-hong, Zhou Yong-gang, Wang Yan. Efficacy of a norvancomycin-loaded, PDLLA-coated plate in preventing early infection of rabbit tibia fracture.. Orthopedics. 2010. DOI: 10.3928/01477447-20100329-06.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.