MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.brs.0000224516.29747.52

Медицинская библиотека · Spine · 2006

Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw.

Yoshida Makoto, Neo Masashi, Fujibayashi Shunsuke, Nakamura Takashi

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

STUDY

DESIGN

We evaluated the trajectories of atlantoaxial transarticular and C2-pedicle screws in 3 dimensions using computerized tomography.

OBJECTIVE

To compare the anatomic risk for vertebral artery injury associated with C2-pedicle and atlantoaxial transarticular screws.

SUMMARY OF BACKGROUND DATA: The atlantoaxial fixation technique using C1-lateral mass screws combined with C2-pedicle screws is considered a safer technique for preventing vertebral artery injury than atlantoaxial transarticular fixation. However, few reports have compared the anatomic risk of vertebral artery injury associated with C2-pedicle screws with that of transarticular screws.

METHODS

A total of 62 consecutive patients with cervical lesions were evaluated using 3-dimensional images reconstructed by a computer-assisted navigation system. We compared the maximum possible diameters of the atlantoaxial transarticular screw and C2-pedicle screw trajectories, and examined whether the maximum possible diameters were limited by the height or width of the bony structure in screw trajectories < or = 4 mm in diameter.

RESULTS

Mean maximum possible diameters did not differ significantly between the trajectories of 124 atlantoaxial transarticular and 124 C2-pedicle screws. In screw trajectories < or = 4 mm in diameter, 57.1% of transarticular screw trajectories were limited by the height of the bony structure, and all pedicle screw trajectories were limited by the width.

CONCLUSIONS

C2-pedicle screw placement has nearly the same anatomic risk of vertebral artery injury as transarticular screw placement. Preoperative 3-dimensional evaluation may be useful for choosing the best surgical technique.

Для цитирования: Yoshida Makoto, Neo Masashi, Fujibayashi Shunsuke, Nakamura Takashi. Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw.. Spine. 2006. DOI: 10.1097/01.brs.0000224516.29747.52.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.