Near-infrared spectroscopy monitoring during endovascular treatment for acute ischaemic stroke.

Collette Sabine L, Venema Allart M, Eleveld Nick, Absalom Anthony R, Scheeren Thomas Wl, Verhoeve Simon, de Groot Jan Cees, Elting Jan Willem J, Uyttenboogaart Maarten, Bokkers Reinoud Ph, Sahinovic Marko M

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The aim of endovascular treatment (EVT) for acute ischaemic stroke is to relieve the cerebral tissue hypoxia in the area supplied by the occluded artery. Near-infrared spectroscopy (NIRS) monitoring is developed to assess regional cerebral tissue oxygen haemoglobin saturation (rSO2). We aimed to investigate whether NIRS can detect inter- and intra-hemispheric rSO2 differences during EVT.

PATIENTS AND

METHODS

In this prospective, observational study, patients undergoing EVT for a proximal intracranial occlusion of the anterior circulation between May 2019 and November 2020, were included. A four-wavelength NIRS monitor (O3® Regional Oximeter (Masimo, Irvine, CA)) was used to measure rSO2 during EVT with sensors placed over the temporal lobes in 20 patients and over the frontal lobes in 13 patients. The Wilcoxon signed-rank test was used to test for inter-hemispheric rSO2 differences after groin puncture and after recanalisation, and intra-hemispheric rSO2 changes before and after recanalisation.

RESULTS

In the temporal cohort, no inter-hemispheric rSO2 differences were observed after groin puncture (median [IQR] rSO2 affected hemisphere, 70% [67-73] and unaffected hemisphere, 70% [66-72]; p = 0.79) and after recanalisation. There were no intra-hemispheric rSO2 changes over time. In the frontal cohort, no inter- and intra-hemispheric rSO2 differences or changes were found.

DISCUSSION AND

CONCLUSION

A NIRS monitor could not detect inter- and intra-hemispheric rSO2 differences or changes during EVT, irrespective of the sensor position. It is likely that even with temporal sensor application, a significant proportion of the received NIRS signal was influenced by oxygenation of surrounding tissues.

Для цитирования: Collette Sabine L, Venema Allart M, Eleveld Nick, Absalom Anthony R, Scheeren Thomas Wl, Verhoeve Simon, de Groot Jan Cees, Elting Jan Willem J, Uyttenboogaart Maarten, Bokkers Reinoud Ph, Sahinovic Marko M. Near-infrared spectroscopy monitoring during endovascular treatment for acute ischaemic stroke.. European stroke journal. 2022. DOI: 10.1177/23969873221107824.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.