BACKGROUND

The single-device simplicity for mechanical thrombectomy (MT) is now challenged by the complementary efficacy of dual-device first-line with a stent retriever and an aspiration catheter.

OBJECTIVE

To compare the outcomes after MT initiated with a single device vs dual devices in acute anterior circulation large vessel occlusion.

METHODS

Patients who underwent MT for acute internal carotid artery (ICA) or M1 occlusion between 2015 and 2020 were retrospectively analyzed. We divided patients into 2 groups: single-device first-line, defined as patients who underwent first-device pass with either a stent retriever or aspiration catheter, and dual-device first-line, defined as first-device pass with both devices.

RESULTS

One hundred forty-one patients were in the single-device group, and 119 were in the dual-device group. In the dual-device group, coiling or kinking of the extracranial ICA was more frequent ( P = .07) and the guide catheters were less frequently navigated to the ICA ( P < .001). 37% of the single-device group was converted to dual-device use. The proportions of mTICI ≥ 2c after the first pass were similar (33% vs 32%. adjusted odds ratio 0.91, 95% CI 0.51-1.62). An mRS score of 0 to 2 at 3 months was achieved similarly (53% vs 48%, P = .46). The total cost for thrombectomy devices was lower in the single-device group ( P < .001).

CONCLUSION

The proportions of first-pass mTICI ≥ 2c were not different between the 2 groups with similar functional outcomes, although the dual-device group more likely to have unfavorable vascular conditions.

Для цитирования: Ohta Tsuyoshi, Tanaka Kanta, Koge Junpei, Yoshimoto Takeshi, Kushi Yuji, Shiozawa Masayuki, Inoue Manabu, Satow Tetsu, Iihara Koji, Ihara Masafumi, Koga Masatoshi, Toyoda Kazunori, Kataoka Hiroharu. Stent Retriever or Aspiration Catheter Alone vs Their Combination as the First-Line Thrombectomy in Acute Stroke.. Neurosurgery. 2022. DOI: 10.1227/neu.0000000000002167.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.