MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/ejo.5000990

Медицинская библиотека · European journal of ophthalmology · 2017

Technical feasibility of isolated Bowman layer graft preparation by femtosecond laser: a pilot study.

Parker Jack S, Huls Forest, Cooper Elizabeth, Graves Paul, Groeneveld-van Beek Esther A, Lie Jessica, Melles Gerrit R J

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the technical feasibility of isolated Bowman layer (BL) graft preparation by femtosecond laser (FSL) and to compare the ultrastructural morphology to manually dissected grafts.

METHODS

Five whole globes were placed in custom-made eye holders and debrided of epithelium. After programming a dissection depth of 20 μm, the FSL was docked into position and 5 isolated BL grafts were created. From 5 additional globes, corneoscleral buttons were procured, mounted in artificial anterior chambers, and stripped of BL via the previously described manual technique. Three specimens from both series were randomly selected and assigned to transmission electron microscopy for ultrastructural evaluation and thickness measurements.

RESULTS

All dissections were uneventful and 10 total grafts were produced: 5 by FSL and 5 by manual dissection. Mean graft thickness was 37 (±8.6) μm (n = 3) for the FSL group and 11.7 (±1.6) μm (n = 3) for the manually dissected group. Transmission electron microscopy revealed a thick but relatively smooth posterior cut edge in the FSL group, versus a virtually isolated BL with irregular rests of dispersed stroma in the manually dissected group.

CONCLUSIONS

Femtosecond laser may have potential for harvesting intact BL and with a smooth posterior surface, but accompanied by variable amounts of anterior stroma owing to technical limitations.

Для цитирования: Parker Jack S, Huls Forest, Cooper Elizabeth, Graves Paul, Groeneveld-van Beek Esther A, Lie Jessica, Melles Gerrit R J. Technical feasibility of isolated Bowman layer graft preparation by femtosecond laser: a pilot study.. European journal of ophthalmology. 2017. DOI: 10.5301/ejo.5000990.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.