DOI 10.1055/s-0036-1580604

Медицинская библиотека · The Thoracic and cardiovascular surgeon · 2016

Large-Animal Biventricular Working Heart Perfusion System with Low Priming Volume-Comparison between in vivo and ex vivo Cardiac Function.

Abicht Jan-Michael, Mayr Tanja Axinja Jelena, Jauch Judith, Guethoff Sonja, Buchholz Stefan, Reichart Bruno, Bauer Andreas

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеVideo-Audio MediaПеревод пока не подготовлен

Аннотация

BACKGROUND

Existing large-animal, ex vivo, cardiac perfusion models are restricted in their ability to establish an ischemia/reperfusion condition as seen in cardiac surgery or transplantation. Other working heart systems only challenge one ventricle or require a substantially larger priming volume. We describe a novel biventricular cardiac perfusion system with reduced priming volume.

METHODS

Juvenile pig hearts were cardiopleged, explanted, and reperfused ex vivo after 150 minutes of cold ischemia. Autologous whole blood was used as perfusate (minimal priming volume 350 mL). After 15 minutes of Langendorff perfusion (LM), the system was switched into a biventricular working mode (WM) and studied for 3 hours.

RESULTS

During reperfusion, complete unloading of both ventricles and constant-pressure coronary perfusion was achieved. During working mode perfusion, the preload and afterload pressure of both ventricles was controlled within the targeted physiologic range. Functional parameters such as left ventricular work index were reduced in ex vivo working mode (in vivo: 787 ± 186 vs. 1 h WM 498 ± 66 mm Hg·mL/g·min; p < 0.01), but remained stable throughout the following study period (3 h WM 517 ± 103 mm Hg·mL/g·min; p = 0.63). Along with the elevated workload during WM, myocardial metabolism and oxygen consumption increased compared with LM (0.021 ± 0.08 vs. 0.06 ± 0.01 mL/min/g; 1 h after reperfusion). Histologic examination of the myocardium revealed no structural damage.

CONCLUSION

In the ex vivo perfusion system, stable hemodynamic and metabolic conditions can be established for a period of 3 hours while functional and blood parameters are easily accessible. Moreover, because of the minimal priming volume, the novel ex vivo cardiac perfusion circuit allows for autologous perfusion, using the limited amount of blood available from the organ donating animal.

Для цитирования: Abicht Jan-Michael, Mayr Tanja Axinja Jelena, Jauch Judith, Guethoff Sonja, Buchholz Stefan, Reichart Bruno, Bauer Andreas. Large-Animal Biventricular Working Heart Perfusion System with Low Priming Volume-Comparison between in vivo and ex vivo Cardiac Function.. The Thoracic and cardiovascular surgeon. 2016. DOI: 10.1055/s-0036-1580604.