MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jjco/hyv212

Медицинская библиотека · Japanese journal of clinical oncology · 2016

Laparoscopic gastrointestinal anastomoses using knotless barbed absorbable sutures are safe and reproducible: a single-center experience with 242 patients.

Lee Sang-Woong, Kawai Masaru, Tashiro Keitaro, Nomura Eiji, Tokuhara Takaya, Kawashima Satoshi, Tanaka Ryo, Uchiyama Kazuhisa

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Intracorporeal reconstruction of the digestive tract is technically challenging. The V-Loc 180 wound closure device (Covidien) is a self-anchoring unidirectional barbed suture that obviates the need for knot tying. The aim of this prospective cohort study was to investigate the use of the novel suture in gastrointestinal enterotomy closure.

METHODS

The subjects comprised patients with malignant disease who were scheduled to undergo laparoscopic gastrectomy with curative intent. The barbed suture was used to close the entry hole for the linear stapler during intracorporeal reconstruction following laparoscopic gastric resection. The primary endpoint was the proportion of patients who developed anastomotic leakage at the site where the barbed suture was applied.

RESULTS

Between July 2012 and March 2015, 242 patients were enrolled. Of 362 anastomoses, the enterotomy hole at 256 sites was closed using the barbed suture. These 256 sites consisted of 95 gastroduodenostomies, 25 gastrogastrostomies, 13 gastrojejunostomies, 90 jejunojejunostomies, 17 esophagojejunostomies and 16 primary closures of the stomach following local gastric resection. There were no anastomosis-related complications, conversion to usual sutures, mechanical closure of the entry hole and reoperation due to adhesive obstructions or mortality over a median follow-up period of 17.8 months.

CONCLUSIONS

The use of the unidirectional barbed absorbable suture for gastrointestinal closure is safe and effective in laparoscopic gastrectomy.

Для цитирования: Lee Sang-Woong, Kawai Masaru, Tashiro Keitaro, Nomura Eiji, Tokuhara Takaya, Kawashima Satoshi, Tanaka Ryo, Uchiyama Kazuhisa. Laparoscopic gastrointestinal anastomoses using knotless barbed absorbable sutures are safe and reproducible: a single-center experience with 242 patients.. Japanese journal of clinical oncology. 2016. DOI: 10.1093/jjco/hyv212.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.