DOI 10.1513/annalsats.202212-1047oc
Ultrasonic Elastography-guided Pleural Biopsy for the Diagnosis of Pleural Effusion: A Multicenter Prospective Study of Diagnostic Test Performance.
Аннотация
Rationale: The diagnostic yield of traditional ultrasound-guided pleural biopsy remains unsatisfactory, particularly when the pleural thickness is ⩽5 mm and/or no pleural nodules are detected. Pleural ultrasound elastography (UE) has a better diagnostic yield than traditional ultrasound for malignant pleural effusion (MPE). However, studies on UE-guided pleural biopsies are lacking.
Objectives
To evaluate the feasibility and safety of UE-guided pleural biopsy.
Methods
In this multicenter prospective single-arm trial, patients with pleural effusion whose pleural thickness was ⩽5 mm with no pleural nodules were enrolled between July 2019 and August 2021. The diagnostic yield of UE-guided pleural biopsy for pleural effusion and its sensitivity for detecting MPE were evaluated.
Results
Ninety-eight patients (mean age, 62.4 ± 13.2 yr; 65 men) were prospectively enrolled. The diagnostic yield of UE-guided pleural biopsy for making any diagnosis was 92.9% (91/98), and its sensitivity for MPE was 88.7% (55/62). In addition, its sensitivity for pleural tuberculosis was 69.6% (16/23). The rate of postoperative chest pain was acceptable, and there was no pneumothorax.
Conclusions
UE-guided pleural biopsy is a novel technique for diagnosing MPE with good diagnostic yield and sensitivity. Clinical trial registered with https://www.chictr.org.cn (ChiCTR2000033572).