MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1468-1293.2007.00487.x

Медицинская библиотека · HIV medicine · 2007

A standardized, comprehensive magnetic resonance imaging protocol for rapid and precise quantification of HIV-1-associated lipodystrophy.

Bickel M, Eisen J, Stephan C, Crespi C M, Lutz T, Klauke S, Vogl T J, Jacobi V, Yang O O, Staszewski S, Zangos S

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Although multiple methods have been proposed, there is no current gold standard for assessing HIV-1-associated lipodystrophy.

METHODS

HIV-1-infected participants were randomly enrolled and surveyed about changes in the abdomen, thigh, cheek and neck areas. Magnetic resonance imaging (MRI) sequences of these sites were obtained. Participants were grouped according to survey results, and the MRI measurements were compared between groups.

RESULTS

One hundred participants were included in the study, of whom 79% reported any body fat changes. Persons reporting increased abdominal girth had higher visceral ([mean+/-standard deviation] 142+/-75 vs. 59+/-48 cm2; P<0.0001) and total abdominal adipose tissue than those reporting no change (344+/-119 vs. 201+/-95 cm2; P<0.0001). The amount of localized fat was less for persons reporting sunken cheeks and reduced diameter of the legs compared with those who noted no changes (5.9+/-3.6 vs. 9.3+/-3.8 cm2; P<0.0001, and 35+/-28 vs. 112+/-56 cm2; P<0.0001). Participants reporting increased neck girth had a thicker fat layer in the dorsocervical region compared with those reporting no change (4.0+/-1.8 vs. 2.3+/-1.4 cm; P<0.0002).

CONCLUSIONS

MRI is a precise method for rapidly surveying body regions affected by HIV-1-associated lipodystrophy. Our proposed protocol provides a rapid, comprehensive survey of these areas, without the need to combine multiple modalities or to expose subjects to radiation.

Для цитирования: Bickel M, Eisen J, Stephan C, Crespi C M, Lutz T, Klauke S, Vogl T J, Jacobi V, Yang O O, Staszewski S, Zangos S. A standardized, comprehensive magnetic resonance imaging protocol for rapid and precise quantification of HIV-1-associated lipodystrophy.. HIV medicine. 2007. DOI: 10.1111/j.1468-1293.2007.00487.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.