Morphometric analysis of aortic media in patients with bicuspid and tricuspid aortic valve.

Bauer Matthias, Pasic Miralem, Meyer Rudolf, Goetze Nadine, Bauer Ulrike, Siniawski Henryk, Hetzer Roland

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Patients with bicuspid aortic valves tend to develop dilatation of the ascending aorta. The aim of this study was to analyze whether or not there is any histologic difference in the aortic media of patients with a bicuspid aortic valve or a tricuspid aortic valve.

METHODS

A morphometric analysis of the wall of the ascending aorta was performed in 107 patients with bicuspid aortic valves undergoing aortic valve operations. The thickness of the elastic lamellae of the aortic media and the distances between the elastic lamellae were measured with the use of an image analysis system. The histologic specimens of the ascending aorta from 61 surgical patients with tricuspid aortic valve disease served as a control.

RESULTS

The patients with bicuspid aortic valves had thinner elastic lamellae of the aortic media (2.71 +/- 0.23 microm) of the ascending aortic wall than the patients with tricuspid aortic valve disease (2.83 +/- 0.23 microm) (p = 0.006). The patients with bicuspid aortic valves also had greater distances between the elastic lamellae (27.21 +/- 8.69 microm) of the ascending aortic wall in comparison with the patients with tricuspid aortic valve disease (24.34 +/- 5.32 microm) (p = 0.033). There was no difference in the total thickness of the aortic media between the groups (p = 0.62).

CONCLUSIONS

Patients with a bicuspid aortic valve had thinner elastic lamellae of the aortic media and greater distances between the elastic lamellae than patients with a tricuspid aortic valve.

Для цитирования: Bauer Matthias, Pasic Miralem, Meyer Rudolf, Goetze Nadine, Bauer Ulrike, Siniawski Henryk, Hetzer Roland. Morphometric analysis of aortic media in patients with bicuspid and tricuspid aortic valve.. The Annals of thoracic surgery. 2002. DOI: 10.1016/s0003-4975(02)03650-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.