MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Revista espanola de enfermedades digestivas · 1998

Hemodynamic monitoring in a model of shock induced by intestinal reperfusion in the rat.

Ulibarrena M A, García-Alonso I, Portugal V, García Redondo B, Méndez J

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

An experimental model to monitor hemodynamics during intestinal reperfusion syndrome is presented.

EXPERIMENTAL

DESIGN

A) Three groups of rats were monitored during four hours: 1) CONTROL: sham operated, 2) Ischemic: clamping the superior mesenteric artery for 60' and 3) Saline: adding 2 ml of saline during the last 15' minutes of ischemia. Blood mean pressure, heart rate, breath rate and diuresis are monitored, while mortality is assessed 48 hours later, B) Blood gases, haematimetry and electrolytes were assessed both in control animals and in rats subjected to intestinal ischemia and reperfusion (at the beginning and concluding the ischemic period, and 5', 60' and 180' following reperfusion).

RESULTS

Mortality rate was 0% for control animals, while 83% for both ischemic-reperfused groups (p < 0.01). Hemodynamic parameters remained stable during intestinal ischemia. Starting reperfusion, blood pressure and diuresis dropped sharply, while heart and breath rates showed a steady increase. The other parameters assessed also remained constant during ischemia. However, during reperfusion acidosis progressed (pH = 7.15, p < 0.01; HCO3 = 8, p < 0.01), hyperkalaemia appeared (6 mEq/l, p < 0.01), and haematocrit rose (56%, p < 0.01).

CONCLUSION

This experimental model is easy to establish, allows an appropriate hemodynamic monitoring of shock during intestinal reperfusion syndrome, and seems appropriate for considering the impact of drug intervention.

Для цитирования: Ulibarrena M A, García-Alonso I, Portugal V, García Redondo B, Méndez J. Hemodynamic monitoring in a model of shock induced by intestinal reperfusion in the rat.. Revista espanola de enfermedades digestivas. 1998.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.