m+Medelevator.RU
← Поиск публикаций
Pacing and clinical electrophysiology : PACE · 2018

P-wave and interatrial block: New predictor for atrial high rate episodes in patients with cardiac implantable electronic devices.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rubio Campal José M, Benezet-Mazuecos Juan, Iglesias Bravo José Antonio, Sánchez Borque Pepa, Miracle Blanco Ángel, de la Vieja Alarcón Juan José, Martínez Mariscal Jaime, Baranchuk Adrian M, Farré Muncharaz Jerónimo

Аннотация

BACKGROUND: The presence of interatrial block (IAB) is associated with the development of atrial fibrillation (AF). The aim of this study was to determine whether P-wave duration and presence of IAB before the implantation of a cardiac implantable electronic device (CIED) are associated with the presence of atrial high rate episodes (AHRE), during long-term follow-up.

METHODS: 380 patients (57% men; 75 ± 10 years) were included. IAB was defined according to the International Consensus Criteria. AHRE was defined as an episode of atrial rate ≥225 beats/min with a minimum duration of 5 minutes.

RESULTS: Documented paroxysmal AF before the implantation was present in 24% of the patients; 80% had hypertension and 32% structural heart disease. Mean P-wave duration was 123 ± 23 ms, and 39% of the patients had IAB (32% partial, 7% advanced). After a mean follow-up of 18 ± 12 months, 33% of the patients presented AHRE. Patients with AHRE had a P-wave duration significantly longer (130 ± 24 ms vs 119 ± 21 ms; P < 0.001) and a greater prevalence of IAB (53% vs 32%; P < 0.001). In a multivariate analysis, predictors of AHRE were: IAB (odds ratio [OR] 2.1; 95% confidence interval [CI] [1.3-3.4], P < 0.001) and previous paroxysmal AF (OR 2.6; 95% CI [1.5-4.3], P < 0.001). In patients without previous AF, the presence of IAB was also a significant predictor of AHRE (OR 3.1; 95% CI [1.8-5.5], P < 0.001).

CONCLUSIONS: IAB is a strong predictor of AHRE in patients with CIED. This finding is independent of the presence of prior paroxysmal AF.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049