Usefulness of Pointwise Encoding Time Reduction with Radial Acquisition-Magnetic Resonance Angiography after Endovascular Treatment for Intracranial Aneurysms.

Heo Young Jin, Kim Donghyun, Jeong Hae Woong, Baek Jin Wook, Kim Da Som, Shin Gi Won, Han Ji-Yeon, Kim Sung Tae, Jeong Young Gyun

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Imaging follow-up after endovascular treatment is important; however, time-of-flight magnetic resonance angiography (TOF-MRA) has limitations associated with magnetic susceptibility and radiofrequency shielding caused by the stent and coils. We evaluated the diagnostic performance of pointwise encoding time reduction with radial acquisition (PETRA)-MRA after endovascular treatment for intracranial aneurysms.

MATERIAL AND

METHODS

A total of 186 patients with 211 aneurysms who underwent both pointwise encoding time reduction with radial acquisition- and time-of-flight magnetic resonance angiography in the same imaging session for follow-up after endovascular treatment. We subjectively graded the overall image quality, visualization of treated sites, and occlusion status.

RESULTS

Although the overall image quality scores of pointwise encoding time reduction with radial acquisition-magnetic resonance angiography were significantly lower than those of time-of-flight magnetic resonance angiography for both observers (4.04 ± 0.81 vs. 4.85 ± 0.35 [observer 1], 4.60 ± 0.69 vs. 4.94 ± 0.24 [observer 2]) (both P < .001), the visibility of treated sites using pointwise encoding time reduction with radial acquisition-magnetic resonance angiography was significantly better than that of time-of-flight magnetic resonance angiography overall (4.27 ± 0.97 vs. 3.42 ± 1.01; P < .001), in the distal internal carotid artery (4.46 ± 0.79 vs. 3.40 ± 1.00; P < .001), and in the middle cerebral artery (4.19 ± 0.93 vs. 3.08 ± 0.53, P = 0.007). Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed a higher area under the curve than time-of-flight magnetic resonance angiography for the evaluation of treated aneurysm occlusion, except for posterior circulation aneurysms.

CONCLUSIONS

Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed better visualization of treated sites and better diagnostic performance than time-of-flight magnetic resonance angiography for anterior circulation aneurysms. However, Pointwise encoding time reduction with radial acquisition-magnetic resonance angiography showed limitations in the follow-up evaluation of posterior circulation aneurysms.

Для цитирования: Heo Young Jin, Kim Donghyun, Jeong Hae Woong, Baek Jin Wook, Kim Da Som, Shin Gi Won, Han Ji-Yeon, Kim Sung Tae, Jeong Young Gyun. Usefulness of Pointwise Encoding Time Reduction with Radial Acquisition-Magnetic Resonance Angiography after Endovascular Treatment for Intracranial Aneurysms.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2021. DOI: 10.1177/15910199211065906.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.