Optimization of 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) for vessel-selective visualization of the internal carotid artery and vertebrobasilar artery systems.

Murazaki Hiroo, Wada Tatsuhiro, Togao Osamu, Obara Makoto, Helle Michael, Yamashita Yasuo, Kobayashi Kouji, Nishie Akihiro, Ishigami Kousei, Kato Toyoyuki

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: This study investigated the optimal labeling position and gradient moment for 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) for vessel-selective flow visualization of the internal carotid artery (ICA) and vertebrobasilar artery (VBA) systems.

METHODS

Seven healthy volunteers were scanned with a 3.0 T MR scanner. To visualize the ICA system, the labeling focus was placed in the right ICA at 55, 75 and 95 mm below the imaging slab. To visualize the VBA system, the labeling focus was placed in the basilar artery (BA), upper vertebral artery (VA upper), and lower vertebral artery (VA lower). Two sizes of labeling focus were created using gradient moments of 0.5 and 0.75 mT/m ms. The contrast-to-noise ratio (CNR) was measured in the middle cerebral artery (MCA) and posterior cerebral artery (PCA) branches.

RESULTS

CNRs increased as the distance between the center of the imaging slab and the labeling position decreased in all MCA segments. CNRs obtained with VA lower tended to be higher than those obtained with BA and VA upper in all PCA segments. Selective vessel visualization was achieved with the gradient moment of 0.75 mT/m ms for the ICA and VBA system.

CONCLUSION

The optimal 4D-S-PACK gradient moment was found to be 0.75 mT/m ms for the ICA and VBA systems. When visualizing the ICA system, the labeling position should be placed as close as possible to the imaging slab. When visualizing the VBA system, the labeling position should be placed at VA lower .

Для цитирования: Murazaki Hiroo, Wada Tatsuhiro, Togao Osamu, Obara Makoto, Helle Michael, Yamashita Yasuo, Kobayashi Kouji, Nishie Akihiro, Ishigami Kousei, Kato Toyoyuki. Optimization of 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) for vessel-selective visualization of the internal carotid artery and vertebrobasilar artery systems.. Magnetic resonance imaging. 2021. DOI: 10.1016/j.mri.2021.10.040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.