MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apmr.2025.08.018

Медицинская библиотека · Archives of physical medicine and rehabilitation · 2025

Effect of Transfemoral Adjustable-Volume Sockets on Socket Comfort and Quality of Life: A Randomized Controlled Trial.

Gates Deanna H, Wensman Jeffrey, Gutierrez Anthony R, Kartes Jordan, Avalos Marco A, Rosenblatt Noah J

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

To determine if adjustable-volume sockets affect patient comfort and quality of life.

DESIGN

Randomized controlled trial.

SETTING

Two prosthetics clinics and 2 research laboratories.

PARTICIPANTS

A convenience sample of individuals with unilateral transfemoral amputation who used prescribed conventional laminated sockets or adjustable-volume sockets (N=29).

INTERVENTIONS: Each participant was fitted with 3 commercially available adjustable-volume prosthetic sockets that were each used at home for separate 4-week trials. Adjustable socket styles included the Infinite Socket (LIM Innovations), CJ Sail (CJ Socket Technologies), and Quatro (Quorum).

MAIN OUTCOME MEASURES: The primary outcomes were Socket Fit Comfort Score, Prosthetic Evaluation Questionnaire (PEQ) subscales, socket-specific individual questions from the PEQ, and health-related quality of life (36-Item Short-Form Health Survey). Assessments were conducted after at least 3 weeks of socket use.

RESULTS

Participants abandoned a large number of sockets during the acclimation due to discomfort or instability: CJ (41%), Infinite Socket (25%), and Quatro (24%). When successful, CJ and Quatro sockets improved the Utility, Ambulation, and Social Burden PEQ subscales as well as fit, feel, and sitting comfort compared with the laminated socket. There were a few differences in the Infinite Socket, though it was perceived as having a poorer appearance. Participants who selected adjustable designs at the conclusion of the study reported measurable improvements in socket comfort.

CONCLUSIONS

Adjustable-volume sockets offer an alternative to conventional laminated sockets that can positively affect comfort, perceived mobility, and prosthetic utility. Future work should identify the characteristics of individuals that predict success with different socket designs.

Для цитирования: Gates Deanna H, Wensman Jeffrey, Gutierrez Anthony R, Kartes Jordan, Avalos Marco A, Rosenblatt Noah J. Effect of Transfemoral Adjustable-Volume Sockets on Socket Comfort and Quality of Life: A Randomized Controlled Trial.. Archives of physical medicine and rehabilitation. 2025. DOI: 10.1016/j.apmr.2025.08.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.