Comparative study by FEM of different liners of a transfemoral amputated lower limb.

Cherif Aichouba Adda, Abdelmadjid Moulgada, El Sallah Zagane Mohammed, Ali Benouis, Yaylacı Murat, Abderahmane Sahli, Özdemir Mehmet Emin, Dizdar Ayberk, Yaylacı Ecren Uzun, Güvercin Yılmaz

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

The mechanical behavior of prosthetic liners significantly influences stress distribution, soft tissue protection, and the overall efficiency of the prosthetic. While extensive research has been conducted on liner materials, the impact of liner thickness (2 mm, 4 mm, and 6 mm) on biomechanical response remains underexplored. This study utilizes finite element analysis in Abaqus to investigate how liner material (Gel vs. Silicone) and thickness affect contact pressure (CPRESS), maximum principal strain (Le. Max), shear stress (CSHEAR1), and vertical displacement (U3) at the residual limb-liner interface. A three-dimensional numerical model was developed to simulate stress transmission and displacement behavior under physiological loading conditions. The results demonstrate that liner thickness plays a critical role in modulating pressure distribution and mechanical stability, with Gel providing superior flexibility and shock absorption, whereas Silicone offers enhanced structural integrity. At a thickness of 2 mm, the highest pressure of 0.4656 MPa is recorded. When the thickness is increased to 4 mm, the pressure decreases to 0.4153 MPa, reflecting a reduction of approximately 10.8%. Further increasing the thickness to 6 mm results in a pressure drop of 0.3825 MPa, corresponding to a total reduction of 17.9%. These findings provide quantitative insights into stress attenuation mechanisms, contributing to the optimization of prosthetic liner design for improved clinical outcomes in lower-limb amputees.

Для цитирования: Cherif Aichouba Adda, Abdelmadjid Moulgada, El Sallah Zagane Mohammed, Ali Benouis, Yaylacı Murat, Abderahmane Sahli, Özdemir Mehmet Emin, Dizdar Ayberk, Yaylacı Ecren Uzun, Güvercin Yılmaz. Comparative study by FEM of different liners of a transfemoral amputated lower limb.. Scientific reports. 2025. DOI: 10.1038/s41598-025-15974-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.