MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11748-008-0261-8

Медицинская библиотека · General thoracic and cardiovascular surgery · 2008

Aortic valve replacement for aortic stenosis in the elderly: influence of prosthesis-patient mismatch on late survival and left ventricular mass regression.

Kato Yasuyuki, Tsutsumi Yasushi, Kawai Takahiro, Goto Tomoyuki, Takahashi Yosuke, Ohashi Hirokazu

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Controversy still exists about the influence of prosthesis-patient mismatch on outcomes after aortic valve replacement in the elderly. Our aim was to evaluate the effect of prosthesis-patient mismatch on survival and the extent of left ventricular (LV) mass regression after aortic valve replacement for aortic stenosis in Japanese patients aged >or=65 years.

MATERIALS AND

METHODS

A total of 84 patients who underwent isolated aortic valve replacement for aortic stenosis between 1986 and 2006 were retrospectively analyzed. Patients were divided into two groups based on the definition of prosthesis-patient mismatch (indexed effective orifice area <or=0.85 cm(2)/m(2)), and long-term results were compared. The mean follow-up time was 4.5 +/- 4.5 years. In 49 patients, follow-up echocardiography was performed at least 6 months after surgery, and the extent of LV mass regression was analyzed according to the presence of a prosthesis-patient mismatch.

RESULTS

Eight years after surgery, there was no significant difference between patients with and without mismatch in terms of actuarial freedom from cardiac-related death (P = 0.159) or death from any valve-related events (P = 0.107). The postoperative transvalvular pressure gradients were not significantly different between the two groups, and significant absolute and relative LV mass regression were observed in both groups.

CONCLUSION

Although a moderate prosthesis-patient mismatch appeared to be tolerable, the criteria of prosthesis-patient mismatch may have to be reassessed for elderly Japanese patients.

Для цитирования: Kato Yasuyuki, Tsutsumi Yasushi, Kawai Takahiro, Goto Tomoyuki, Takahashi Yosuke, Ohashi Hirokazu. Aortic valve replacement for aortic stenosis in the elderly: influence of prosthesis-patient mismatch on late survival and left ventricular mass regression.. General thoracic and cardiovascular surgery. 2008. DOI: 10.1007/s11748-008-0261-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.