MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2008.04.017

Медицинская библиотека · International journal of cardiology · 2008

Dysfunction of a bileaflet mechanical valve in mitral position: absence of symptoms despite a completely fixed leaflet.

Magne Julien, Pibarot Philippe, Trahan Sylvain, Sénéchal Mario

Клинический случайПисьмо в редакциюПеревод пока не подготовлен

Аннотация

We report the case of 62 year-old asymptomatic woman with a bileaflet mechanical prosthesis implanted 1 year ago. Routine transthoracic echocardiography (TTE) showed that one leaflet was fixed in semi-closed position, which was confirmed by transesophageal echocardiography (TEE) and cinefluoroscopy. The paradoxical absence of symptoms despite a complete restriction of one leaflet may be due to the fact that this patient had a very small body surface area and received a prosthesis with an excellent hemodynamic performance. The presence of a large compliant left atrial chamber may have also contributed to limit the effects of valve dysfunction on the pulmonary circulation.

Для цитирования: Magne Julien, Pibarot Philippe, Trahan Sylvain, Sénéchal Mario. Dysfunction of a bileaflet mechanical valve in mitral position: absence of symptoms despite a completely fixed leaflet.. International journal of cardiology. 2008. DOI: 10.1016/j.ijcard.2008.04.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.