MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1540-8191.2007.00414.x

Медицинская библиотека · Journal of cardiac surgery · 2007

Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis.

Kato Yasuyuki, Suehiro Shigefumi, Shibata Toshihiko, Sasaki Yasuyuki, Hirai Hidekazu

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM OF THE STUDY: The influence of prosthesis-patient mismatch on long-term results after aortic valve replacement remains controversial. The aim of this study was to evaluate the effect of prosthesis-patient mismatch on survival and the extent of left ventricular mass regression after aortic valve replacement for aortic stenosis.

METHODS

We retrospectively reviewed 146 patients who underwent isolated aortic valve replacement for aortic stenosis between 1990 and 2005. Prosthesis-patient mismatch was defined as an effective orifice area/body surface area <or=0.85 cm(2)/m(2). Mean follow-up was 4.5 +/- 3.3 years, with a total follow-up of 650.0 patient-years. In 108 patients, follow-up echocardiography was performed at least 6 months after surgery, and the extent of postoperative left ventricular mass regression was analyzed according to the presence of prosthesis-patient mismatch.

RESULTS

Ten years after surgery, there was no significant difference between patients with mismatch and those without mismatch in overall survival (p = 0.345), actuarial freedom from cardiac-related death (p = 0.576), and freedom from any valve-related mortality or morbidity (p = 0.614). Using multivariate analysis, PPM was not a predictor of late cardiac-related death or all deaths. Echocardiographic examination showed that left ventricular wall thickness and left ventricular mass was significantly decreased postoperatively in both groups. However, the absolute and relative left ventricular mass regression was significantly lower in patients with mismatch than in those without mismatch.

CONCLUSIONS

This study showed no negative effects of prosthesis-patient mismatch on survival at 10 years after aortic valve replacement for aortic stenosis. However, the extent of left ventricular mass regression was significantly lower in patients with mismatch.

Для цитирования: Kato Yasuyuki, Suehiro Shigefumi, Shibata Toshihiko, Sasaki Yasuyuki, Hirai Hidekazu. Impact of valve prosthesis-patient mismatch on long-term survival and left ventricular mass regression after aortic valve replacement for aortic stenosis.. Journal of cardiac surgery. 2007. DOI: 10.1111/j.1540-8191.2007.00414.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.