Anti-HLA antibodies after cryopreserved allograft valve implantation does not predict valve dysfunction at three-year follow up.

Yap Cheng-Hon, Skillington Peter D, Matalanis George, Davis Bruce B, Tait Brian D, Hudson Fiona, Ireland Lyn, Nixon Ian, Yiil Michael

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM OF THE STUDY: As the cause of allograft heart valve degeneration is poorly understood, the study aim was to investigate the host antibody response to allograft valve implantation.

METHODS

Sera were obtained from 92 recipients of allograft heart valves (61 pulmonary, 31 aortic). Sera were tested for anti-HLA class I antibodies by ELISA and complement-dependent cytotoxicity (CDC) methods, and anti-HLA class II antibodies by ELISA. Specificities of recipient anti-HLA class I antibodies were defined by standard CDC testing against a panel of T lymphocytes from 80 blood donors. Donor valve HLA typing was performed on stored donor DNA samples using molecular methods. The presence of donor-specific anti-HLA class I antibodies was hence defined in recipient sera. The presence of anti-HLA antibodies and donor-specific anti-HLA class I antibodies were correlated with function of allograft valves at the most recent echocardiographic follow up.

RESULTS

At a mean of 3.0 years (range: 0.3-5.4 years) after allograft implantation, 96% (87/92) and 82% (75/92) of patients were positive for anti-HLA class I and II antibodies, respectively, by ELISA testing. Some 68% (61/90) of patients were positive for anti-HLA class I antibody (PRA > 5%) by CDC testing. PRA levels decreased with greater postoperative interval (r = -0.31, p = 0.003). In 68 recipients where donor HLA type was defined, 54% (37/68) of patients had antibodies specific to at least one donor HLA class I antigen. In 87 patients with a recent echocardiographic examination available for analysis (at a mean of 3.5 +/- 1.6 years postoperatively), there was no association between valve dysfunction and antibody status.

CONCLUSION

Anti-HLA class I and II antibodies were detected by ELISA methods in most patients after allograft implantation extending to 5.4 years. The clinical significance of these findings is unclear, as no correlation was found between the prevalence of anti-HLA antibody and echocardiographic parameters of valve dysfunction at a mean of 3.5 years follow up.

Для цитирования: Yap Cheng-Hon, Skillington Peter D, Matalanis George, Davis Bruce B, Tait Brian D, Hudson Fiona, Ireland Lyn, Nixon Ian, Yiil Michael. Anti-HLA antibodies after cryopreserved allograft valve implantation does not predict valve dysfunction at three-year follow up.. The Journal of heart valve disease. 2006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.