DOI 10.1111/j.1540-8191.2006.00216.x
Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement.
Аннотация
BACKGROUND
The aim of this study was to evaluate the frequency of requirement for permanent pacing and related risk factors after aortic valve replacement.
METHODS
Among 465 patients operated between 1994 and 2004, 19(4.1%) patients with a mean age 49.9 +/- 17.2 years required the implantation of a permanent pacemaker. Eleven of them were female (57.9%). The main indication was aortic stenosis (89.5%). Severe annular calcification was documented in 78.9% of them, and the aortic valve was bicuspid in 57.9%.
RESULTS
Risk factors for permanent pacing after aortic valve replacement (AVR) identified by univariate analysis were female sex, hypertension, preoperative ejection fraction, aortic stenosis, annular calcification, bicuspid aorta, presence of right bundle branch block (RBBB) or left bundle branch block (LBBB), prolonged aortic cross-clamp and perfusion times, and preoperative use of calcium channel blockers. Multivariate analysis showed that female sex (p = 0.01, OR; 5.21, 95% CI: 1.48-18.34), annular calcification (p < 0.001, OR; 0.05, 95% CI: 0.01-0.24), bicuspid aortic valve (p = 0.02, OR; 0.24, 95% CI: 0.07-0.84), presence of RBBB (p = 0.009, OR; 0.03, 95% CI: 0.003-0.44) or LBBB (p = 0.01, OR; 0.13, 95% CI: 0.02-0.69), hypertension (p = 0.03, OR; 0.22, 95%CI: 0.05-0.89), and total perfusion time (p = 0.002, OR; 1.05, 95% CI: 1.01-1.08) were associated risk factors.
CONCLUSION
Irreversible atrioventricular block requiring a permanent pacemaker implantation is an uncommon complication after AVR. Risk factors are annular calcification, bicuspid aorta, female sex, presence of RBBB or LBBB, prolonged total perfusion time, and hypertension.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.