MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of heart valve disease · 2006

Hemolysis, high-intensity transient signals (HITS) and hemodynamic results after aortic valve replacement with the Medtronic Hall Easy-Fit heart valve prosthesis.

Warnecke Roland H, Laas Joachim, Hecker Hartmut, Perthel Matthias, Alken Aiman

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM OF THE STUDY: Previous studies have shown a correlation between type, orientation and valve size of mechanical heart valve prostheses and the incidence of high-intensity transient signals (HITS). The study aim was to investigate the presence of HITS and hemolysis and the impact of valve size and hemodynamic parameters following aortic valve replacement (AVR) using the new Medtronic Hall Easy-Fit prosthesis.

METHODS

A total of 150 patients (120 males, 30 females; mean age 62 +/- 8 years; range: 32-78 years) underwent AVR (n = 94; 63% concomitant procedures) with the Easy-Fit valve in its optimal orientation. Patients were investigated at between three and 36 months after AVR using transcranial Doppler examination of the right and left middle cerebral artery, and the incidence of HITS was determined. For evaluation of hemolysis, serum lactate dehydrogenase (LDH), hemoglobin and bilirubin were measured. These parameters were related to valve size. Transthoracic echocardiography was performed in all patients.

RESULTS

Among the patients, 112 (75%) showed no or low HITS (34% none, 41% < 30/h), while only 38 (25%) had elevated HITS (range 31-100/h, 14%; range > 100/h, 11%). Statistical analysis showed a linear association between the HITS count and valve size. A positive correlation between valve size and LDH was observed; hemoglobin and bilirubin showed normal values.

CONCLUSION

The valve size-dependent increase in LDH after AVR corresponds with the observation that the presence of HITS increases with valve size. In light of these findings, the surgical approach to implant the largest size Easy-Fit valve possible should be discussed, given the excellent hemodynamic results provided by the valve, even in smaller sizes.

Для цитирования: Warnecke Roland H, Laas Joachim, Hecker Hartmut, Perthel Matthias, Alken Aiman. Hemolysis, high-intensity transient signals (HITS) and hemodynamic results after aortic valve replacement with the Medtronic Hall Easy-Fit heart valve prosthesis.. The Journal of heart valve disease. 2006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.