MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2004.10.073

Медицинская библиотека · Journal of the American College of Cardiology · 2005

Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement.

Li Mingzhou, Dumesnil Jean G, Mathieu Patrick, Pibarot Philippe

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

We sought to determine the impact of valve prosthesis-patient mismatch (PPM) on pulmonary arterial (PA) pressure after mitral valve replacement (MVR).

BACKGROUND

Pulmonary arterial hypertension is a serious complication of mitral valve disease, and it is a major risk factor for poor outcome after MVR. We hypothesized that valve PPM might be a determinant of PA hypertension after MVR.

METHODS

Systolic PA pressure was measured by Doppler echocardiography in 56 patients with normally functioning mitral prosthetic valves. Mitral valve effective orifice area (EOA) was determined by the continuity equation and indexed for body surface area.

RESULTS

Thirty patients (54%) had PA hypertension defined as systolic PA pressure >40 mm Hg, whereas 40 patients (71%) had PPM defined as an indexed EOA < or =1.2 cm(2)/m(2). There was a significant correlation (r = 0.64) between systolic PA pressure and indexed EOA. The average systolic PA pressure and prevalence of PA hypertension were 34 +/- 8 mm Hg and 19% in patients with no PPM versus 46 +/- 8 mm Hg and 68% in patients with PPM (p < 0.001). In multivariate analysis, the indexed EOA was by far the strongest predictor of systolic PA pressure.

CONCLUSIONS

Persistent PA hypertension is frequent after MVR and strongly associated with the presence of PPM. The clinical implications of these findings are important given that PPM can largely be avoided by using a simple prospective strategy at the time of operation.

Для цитирования: Li Mingzhou, Dumesnil Jean G, Mathieu Patrick, Pibarot Philippe. Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement.. Journal of the American College of Cardiology. 2005. DOI: 10.1016/j.jacc.2004.10.073.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.