Left ventricular outflow tract obstruction due to anomalous insertion of papillary muscle.

Nomura Tetsuya, Harada Yoshiaki, Suzaki Yoko, Hayashi Hironori, Tanaka Hiroyuki, Shiraishi Jun, Komatsu Sumio, Hosomi Yasuo, Hirano Shinji, Yaku Hitoshi, Kitamura Nobuo

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

A 56-year-old man who complained of quadrantic hemianopsia was admitted to determine its etiology. Cerebral angiography revealed no organic stenosis. Echocardiography showed clear direct continuity between a hypertrophied anterolateral papillary muscle and the anterior mitral leaflet, and the left ventricular (LV) outflow tract (LVOT) was narrowed by the presence of an accessory papillary muscle. The LVOT obstruction caused an intra-LV pressure overload that resulted in LV concentric hypertrophy. Arrhythmia, such as paroxysmal atrial fibrillation (PAF), was thought to have caused a cerebral embolism. Mitral valve replacement (MVR), septal myectomy, and myectomy of the abnormal papillary muscle were performed, and complete release of the LVOT obstruction was accomplished. Anomalous insertion of papillary muscle is a rare cause of LVOT obstruction. Echocardiography was useful in identifying the papillary muscle malformation, and surgery was completely curative.

Для цитирования: Nomura Tetsuya, Harada Yoshiaki, Suzaki Yoko, Hayashi Hironori, Tanaka Hiroyuki, Shiraishi Jun, Komatsu Sumio, Hosomi Yasuo, Hirano Shinji, Yaku Hitoshi, Kitamura Nobuo. Left ventricular outflow tract obstruction due to anomalous insertion of papillary muscle.. Circulation journal : official journal of the Japanese Circulation Society. 2004. DOI: 10.1253/circj.68.1219.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.