OBJECTIVE

To measure cardiac output and other hemodynamic variables in anesthetized dogs undergoing laparotomy because of abdominal neoplasia.

DESIGN

Prospective case series.

ANIMALS: 8 dogs with splenic or hepatic tumors.

PROCEDURES: Dogs were anesthetized and underwent abdominal laparotomy. End-tidal isoflurane concentration, heart rate, arterial blood pressures, cardiac output, arterial pH, blood gas partial pressures, PCV, and plasma total protein concentration were measured at set intervals before, during, and after surgery. Cardiac index, stroke index, and systemic vascular resistance index were calculated.

RESULTS

End-tidal isoflurane concentration was lowest before and after surgery. Heart rate did not change significantly throughout the anesthetic period. Arterial blood pressures and systemic vascular resistance index were highest shortly after surgery began; cardiac index and stroke volume index did not change significantly during surgery but increased significantly after surgery ended.

CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that in dogs undergoing laparotomy because of abdominal neoplasia, changes in arterial blood pressures were not necessarily indicative of qualitatively similar changes in cardiac index.

Для цитирования: Wagner Ann E, Miyake Yukari. Cardiac output and other hemodynamic variables in anesthetized dogs undergoing laparotomy because of abdominal neoplasia.. Journal of the American Veterinary Medical Association. 2008. DOI: 10.2460/javma.232.4.547.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.