Assessment of Hydration Status in Peritoneal Dialysis Patients: Validity, Prognostic Value, Strengths, and Limitations of Available Techniques.

Alexandrou Maria-Eleni, Balafa Olga, Sarafidis Pantelis

СтатьяОбзорВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The majority of patients undergoing peritoneal dialysis (PD) suffer from volume overload and this overhydration is associated with increased mortality. Thus, optimal assessment of volume status in PD is an issue of paramount importance. Patient symptoms and physical signs are often unreliable indexes of true hydration status.

SUMMARY: Over the past decades, a quest for a valid, reproducible, and easily applicable technique to assess hydration status is taking place. Among existing techniques, inferior vena cava diameter measurements with echocardiography and natriuretic peptides such as brain natriuretic peptide and N-terminal pro-B-type natriuretic peptide were not extensively examined in PD populations; while having certain advantages, their interpretation are complicated by the underlying cardiac status and are not widely available. Bioelectrical impedance analysis (BIA) techniques are the most studied tool assessing volume overload in PD. Volume overload assessed with BIA has been associated with technique failure and increased mortality in observational studies, but the results of randomized trials on the value of BIA-based strategies to improve volume-related outcomes are contradictory. Lung ultrasound (US) is a recent technique with the ability to identify volume excess in the critical lung area. Preliminary evidence in PD showed that B-lines from lung US correlate with echocardiographic parameters but not with BIA measurements. This review presents the methods currently used to assess fluid status in PD patients and discusses existing data on their validity, applicability, limitations, and associations with intermediate and hard outcomes in this population. Key Message: No method has proved its value as an intervening tool affecting cardiovascular events, technique, and overall survival in PD patients. As BIA and lung US estimate fluid overload in different compartments of the body, they can be complementary tools for volume status assessment.

Для цитирования: Alexandrou Maria-Eleni, Balafa Olga, Sarafidis Pantelis. Assessment of Hydration Status in Peritoneal Dialysis Patients: Validity, Prognostic Value, Strengths, and Limitations of Available Techniques.. American journal of nephrology. 2020. DOI: 10.1159/000509115.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.