Bio-electrical impedance analysis for perioperative fluid evaluation in open major abdominal surgery.

Ciumanghel Adi-Ionut, Grigoras Ioana, Siriopol Dimitrie, Blaj Mihaela, Rusu Daniel-Mihai, Grigorasi Gabriela Raluca, Igna Alexandru Razvan, Duca Oana, Siriopol Ianis, Covic Adrian

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

Water retention and intercompartmental redistribution occur frequently in association with adverse postoperative outcomes, yet the available strategies for non-invasive assessment are limited. One such approach for evaluating body water composition in various circumstances is bio-electrical impedance analysis (BIA). This study aims to appraise the usefulness of the Body Composition Monitor (BCM, Fresenius Medical Care, Germany) in assessing body fluid composition and intercompartmental shifts before and after open major abdominal surgery. This prospective, clinician blinded observational study enrolled all the patients scheduled consecutively for elective major open abdominal surgery during a 1-year period starting from January 1st, 2016. BIA parameters-total body water (TBW), extracellular water (ECW), intracellular water (ICW), absolute fluid overload (AFO), and relative fluid overload (RFO) were measured before and after surgery. The results were compared with fluid balance and outcome parameters such as organ dysfunction, ICU-and hospital length of stay (-LOS). The study population included 71 patients aged 60.2 ± 12 of whom 60.6% men and with a BMI of 26.3 ± 5.1 kg/m2. Postoperative acute kidney injury, respiratory dysfunction, and infections occurred in 14.0%, 19.7% and 28.1% of cases, respectively. The median LOS in ICU was 20 h and the hospital-LOS was 10 days. Positive intraoperative fluid balance (2.4 ± 1.0 L) resulted in a significant increase of TBW (1.4 ± 2.4 L) and of ECW (1.4 ± 1.2 L). Intraoperative fluid balance significantly correlated with TBW change (r = 0.23, p = 0.04) and with AFO change (r = 0.31, p < 0.01). A significant correlation was found between pre- and postoperative AFO and RFO on one hand, and ICU-LOS on the other. BIA may be a useful tool for the perioperative assessment of volume status.

Для цитирования: Ciumanghel Adi-Ionut, Grigoras Ioana, Siriopol Dimitrie, Blaj Mihaela, Rusu Daniel-Mihai, Grigorasi Gabriela Raluca, Igna Alexandru Razvan, Duca Oana, Siriopol Ianis, Covic Adrian. Bio-electrical impedance analysis for perioperative fluid evaluation in open major abdominal surgery.. Journal of clinical monitoring and computing. 2019. DOI: 10.1007/s10877-019-00334-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.