MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjophthalmol-2021-318972

Медицинская библиотека · The British journal of ophthalmology · 2021

Higher contrast thresholds for vanishing optotype recognition in macular visual fields among glaucoma patients: a structure-function analysis.

Wen Yun, Chen Zidong, Chen Shuo, Tan Kaixin, Kong Yang, Cheng Hui, Yu Minbin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: We aimed to explore the impact of glaucomatous macular damage, specifically retinal ganglion cell (RGC) loss, on macular pattern vision measured by the vanishing optotype (VO) recognition contrast threshold.

METHODS

Seventy-two patients (mean age, 33.51±7.05 years) with primary open-angle glaucoma and 36 healthy controls (mean age, 30.25±6.70 years) were enrolled. VO recognition contrast thresholds of each participant were measured at the 16 preset test locations covering the central 5° visual field (VF). Macular sensitivity (MS) was tested by macular threshold test of Humphrey Field Analyzer. Macular RGC plus inner plexiform layer (GCIPL) thickness was also measured by spectral domain optical coherence tomography.

RESULTS

The VO contrast threshold demonstrated weak-to-moderate correlations (rho=-0.275 to -0.653) with MS (p<0.001). There was a significantly higher VO contrast threshold in glaucoma group (p<0.0001). At similar levels of MS, patients with glaucoma with GCIPL damage showed remarkably higher VO contrast thresholds than those with preserved GCIPL (p=0.0079). The structure-function relationships between VO contrast threshold and GCIPL thickness (rho=-0.725 to -0.802) were remarkably stronger than those between MS and GCIPL thickness (rho=0.210 to 0.448). VO contrast threshold showed stronger correlation with average GCIPL thickness (rho=-0.362 to -0.778) than MS (rho=0.238 to 0.398) at multiple test locations in glaucoma group.

CONCLUSIONS

Glaucomatous eyes have higher contrast thresholds for VO recognition in fovea-around VF. Stronger structure-function relationships indicate that VO contrast threshold is more vulnerable to RGC damage.

Для цитирования: Wen Yun, Chen Zidong, Chen Shuo, Tan Kaixin, Kong Yang, Cheng Hui, Yu Minbin. Higher contrast thresholds for vanishing optotype recognition in macular visual fields among glaucoma patients: a structure-function analysis.. The British journal of ophthalmology. 2021. DOI: 10.1136/bjophthalmol-2021-318972.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.