MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1117/1.jbo.27.5.055001

Медицинская библиотека · Journal of biomedical optics · 2022

Toward the development of a polarimetric tool to diagnose the fibrotic human ventricular myocardium.

Bagha Twinkle, Kamal Arif Mohd, Pal Uttam M, Mohan Rao Prasanna Simha, Pandya Hardik J

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

SIGNIFICANCE: Optical polarimetry is an emerging modality that effectively quantifies the bulk optical properties that correlate with the anisotropic structural properties of cardiac tissues. We demonstrate the application of a polarimetric tool for characterizing healthy and fibrotic human myocardial tissues efficiently with a high degree of accuracy.

AIM: The study was aimed to characterize the myocardial tissues from the left ventricle and right ventricle of N  =  7 control and N  =  10 diseased subjects. The diseased subjects were composed of two groups: N  =  7 with rheumatic heart disease (RHD) and N  =  3 with myxomatous valve (MV) disease.

APPROACH: A portable, affordable, and accurate linear polarization-based diagnostic tool is developed to measure the degree of linear polarization (DOLP) of the myocardial tissues while working at a wavelength of 850 nm.

RESULTS

The sensitivity, specificity, and accuracy of the polarimetric tool in distinguishing the control group from the RHD group were found to be 73.33%, 76.92%, and 75%, respectively, and from the MV group were 91.6%, 62.5%, and 80%, respectively, which demonstrates the efficacy of the polarimetric tool to distinguish the healthy myocardial tissues from diseased tissues.

CONCLUSIONS

We have successfully developed a polarimetric tool that can aid cardiologists in characterizing the myocardial tissues in conjunction with endomyocardial biopsy. This work should be followed up with experiments on a large cohort of control and diseased subjects. We intend to create and develop a probe to quantify the DOLP of in vivo heart tissue during surgery.

Для цитирования: Bagha Twinkle, Kamal Arif Mohd, Pal Uttam M, Mohan Rao Prasanna Simha, Pandya Hardik J. Toward the development of a polarimetric tool to diagnose the fibrotic human ventricular myocardium.. Journal of biomedical optics. 2022. DOI: 10.1117/1.jbo.27.5.055001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.