MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/clc.23811

Медицинская библиотека · Clinical cardiology · 2022

Assessing left atrial function in patients with atrial fibrillation and valvular heart disease using cardiovascular magnetic resonance imaging.

Hou Jie, Sun Yu, Zhang Libo, Wang Wei, You Hongrui, Zhang Rongrong, Yang Benqiang, Wang Huishan

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Atrial fibrillation (AF) is common arrhythmia in valvular heart disease (VHD) and is associated with adverse outcomes.

HYPOTHESIS: To evaluate the left atrial (LA) function in patients with AF-VHD by cardiovascular magnetic resonance imaging feature tracking (CMR-FT) using LA strain (εs /εe /εa ) and their corresponding strain rate (SRs/SRe/SRa).

METHODS

This was a retrospective cross-sectional inter-reader and intra-reader reproducibility conducted from July 1, 2020, to January 31, 2021. A total of 39 patients with AF-VHD (rheumatic heart valvular disease [RHVD] [n = 22], degenerative heart valvular disease [DHVD] [n = 17]) underwent MRI scans performed with drug-controlled heart rate before correcting the rhythm and valves through maze procedure. Fifteen participants with normal cardiac MRI were included as healthy control. εs /SRs, εe /SRe, and εa /SRa, corresponding to LA reservoir, conduit, and booster-pump function, were assessed using Feature Tracking software (CVI42 v5.12.1).

RESULTS

Compared with healthy controls, LA global strain parameters (εs /εe /εa /SRs/SRe/SRa) were significantly decreased (all p < 0.001), while LA size and volume were increased in AF-VHD group (all p < 0.001). In the subgroup, RHVD group showed lower LA total ejection fraction (LATEF) and strain data than DHVD group (12.6% ± 3.3% vs. 19.4 ± 8.6, p = 0.001). Decreased LATEF was significantly related to altered LA strain and strain rate, especially in εs , εe , and SRs (Pearson/Spearman r/ρ = 0.856/0.837/0.562, respectively; all p < 0.001). Interstudy and intrastudy reproducibility were consistent for LA volumetry and strain parameters (intraclass correlation coefficient: 0.88-0.99).

CONCLUSIONS

CMR-FT can be used to assess the LA strain parameters, and identify LA dysfunction and deformation noninvasively, which could be a helpful functional imaging biomarker in the clinical treatment of AF-VHD.

Для цитирования: Hou Jie, Sun Yu, Zhang Libo, Wang Wei, You Hongrui, Zhang Rongrong, Yang Benqiang, Wang Huishan. Assessing left atrial function in patients with atrial fibrillation and valvular heart disease using cardiovascular magnetic resonance imaging.. Clinical cardiology. 2022. DOI: 10.1002/clc.23811.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.