INTRODUCTION

Serum creatinine is not enough sensitive marker for the evaluation of glomerular filtration rate (GFR). Cockcroft-Gault (CG) formula is often used to assess GFR, but it is necessary to correct original one for body surface area (BSA), adipositas, and the creatinine tubular secretion. The values of the estimated creatinine clearance and GFR are considered to Poggio reference ones according to biological parameters (age and gender). The aim of the study was to determine the difference in renal function estimation between serum creatinine and corrected CG equation according to the Poggio reference values in the arterial hypertension patients.

MATERIALS AND

METHODS

The research included 124 patients of both gender with arterial hypertension, excluding ones with the already verified chronic kidney disease. We estimated creatinine clearance and GFR by CG method corrected for the BSA, body mass index (BMI), and the creatinine tubular secretion according to Poggio reference values.

RESULTS

There was no significant difference in both age and gender groups among patients with physiological and pathological values of the renal function determined by the serum creatinine and estimated creatinine clearance by CG equation corrected for BMI, BSA. In both age and gender groups there was significant difference among subjects with physiological and pathological values of the renal function determined by serum creatinine and estimated GFR by CG method corrected for BMI, BSA, and creatinine tubular secretion.

CONCLUSION

There is the most striking difference in the assessment of renal function between serum creatinine and estimated GFR by CG method with three corrections (BSA, BMI, the creatinine tubular secretion). Estimated GFR by CG method with three corrections can help in the early diagnosis of renal dysfunction and optimal treatment in patients with arterial hypertension.

Для цитирования: Šečić Damir, Turohan Adnan, Begić Edin, Rebić Damir, Pepić Esad, Begić Zijo, Iglica Amer, Begić Nedim, Metović Azra, Mušanović Jasmin. Serum Creatinine versus Corrected Cockcroft-Gault Equation According to Poggio Reference Values in Patients with Arterial Hypertension.. International journal of applied & basic medical research. 2022. DOI: 10.4103/ijabmr.ijabmr_301_21.