Correlation of tumor maximum standardized uptake value from 18F-BPA PET and boron neutron capture therapy tumor dose with treatment outcomes in head and neck cancer: a retrospective analysis.

Yoshino Yuki, Takeno Satoshi, Aihara Teruhito, Isohashi Kayako, Hu Naonori, Kanai Yasukazu, Sasaki Akinori, Nojiri Mai, Terada Tetsuya, Haginomori Shinichi, Nihei Keiji, Ono Koji

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Boron neutron capture therapy (BNCT) dose planning conventionally uses a tumor-to-blood (T/B) ratio derived from the tumor maximum standardized uptake value (SUVmax) of fluorine-18-labeled 4-borono-L-phenylalanine (1⁸F-BPA) positron emission tomography (PET) (individual model). It remains unclear whether tumor SUVmax or individual model doses predict outcomes in accelerator-based BNCT for head and neck cancer (HNC). We investigated the correlation of 1⁸F-BPA PET SUVmax and individual model doses with treatment response.

MATERIALS AND

METHODS

We retrospectively analyzed 30 patients with HNC treated with accelerator-based BNCT (2020-2021). The Kaplan-Meier method was used for survival analysis. Dose parameters (Dmax, Dmin, and D80%) were calculated using the uniform model (T/B = 2.5) and the individual model (T/B = Tumor SUVmax/Blood-pool SUV). Correlations between tumor SUVmax or dose parameters and best treatment response [complete response (CR) vs. non-CR] were evaluated using the Mann-Whitney U test.

RESULTS

The objective response rate was 90%, and the CR rate was 50%. CR status strongly predicted superior 2 years overall survival, locoregional control, and progression-free survival (all p < 0.05). However, no significant differences were observed between the CR and non-CR groups for tumor SUVmax, uniform model doses, or individual model doses (all p > 0.05).

CONCLUSION

1⁸F-BPA PET SUVmax and the conventional individual model did not demonstrate a statistically significant association with CR in patients with HNC after accelerator-based BNCT. These findings question the utility of tumor SUVmax-based dosimetry, suggesting that current models require refinement.

Для цитирования: Yoshino Yuki, Takeno Satoshi, Aihara Teruhito, Isohashi Kayako, Hu Naonori, Kanai Yasukazu, Sasaki Akinori, Nojiri Mai, Terada Tetsuya, Haginomori Shinichi, Nihei Keiji, Ono Koji. Correlation of tumor maximum standardized uptake value from 18F-BPA PET and boron neutron capture therapy tumor dose with treatment outcomes in head and neck cancer: a retrospective analysis.. Japanese journal of radiology. 2026. DOI: 10.1007/s11604-026-02020-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.