DOI 10.1111/aor.12544

Медицинская библиотека · Artificial organs · 2015

Hemocompatibility of Axial Versus Centrifugal Pump Technology in Mechanical Circulatory Support Devices.

Schibilsky David, Lenglinger Matthias, Avci-Adali Meltem, Haller Christoph, Walker Tobias, Wendel Hans Peter, Schlensak Christian

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

The hemocompatible properties of rotary blood pumps commonly used in mechanical circulatory support (MCS) are widely unknown regarding specific biocompatibility profiles of different pump technologies. Therefore, we analyzed the hemocompatibility indicating markers of an axial flow and a magnetically levitated centrifugal device within an in vitro mock loop. The HeartMate II (HM II; n = 3) device and a CentriMag (CM; n = 3) adult pump were investigated in a human whole blood mock loop for 360 min using the MCS devices as a driving component. Blood samples were analyzed by enzyme-linked immunosorbent assay for markers of coagulation, complement system, and inflammatory response. There was a time-dependent activation of the coagulation (thrombin-antithrombin complexes [TAT]), complement (SC5b-9), and inflammation system (polymorphonuclear [PMN] elastase) in both groups. The mean value of TAT (CM: 4.0 μg/L vs. 29.4 μg/L, P < 0.001; HM II: 4.5 μg/L vs. 232.2 μg/L, P < 0.05) and PMN elastase (CM: 53.4 ng/mL vs. 253.8 ng/mL, P < 0.05; HM II: 28.0 ng/mL vs. 738.8 ng/mL, P < 0.001) significantly increased from baseline until the end of the experiments (360 min). After 360 min, TAT and PMN values were significantly higher in the HM II group compared with the values in the CM adult group. The values of SC5b-9 increased from baseline to 360 min in the CM group (CM: 141.8 ng/mL vs. 967.9 ng/mL, P < 0.05) and the HM II group. However, the increase within the HM II group (97.3 vs. 2462.0, P = 0.06) and the comparison of the 360-min values between CM group and HM II group did not reach significance (P = 0.18). The activation of complement, coagulation, and inflammation system showed a time-dependent manner in both devices. The centrifugal CM device showed significantly lower activation of coagulation and inflammation than that of the HM II axial flow pump. Both HM II and CM have demonstrated an acceptable hemocompatibility profile in patients. However, there is a great opportunity to gain a clinical benefit by developing techniques to lower the blood surface interaction within both pump technologies and a magnetically levitated centrifugal pump design might be superior.

Для цитирования: Schibilsky David, Lenglinger Matthias, Avci-Adali Meltem, Haller Christoph, Walker Tobias, Wendel Hans Peter, Schlensak Christian. Hemocompatibility of Axial Versus Centrifugal Pump Technology in Mechanical Circulatory Support Devices.. Artificial organs. 2015. DOI: 10.1111/aor.12544.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.