MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.12714

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2015

Eligibility for the Subcutaneous Implantable Cardioverter-Defibrillator in Patients With Hypertrophic Cardiomyopathy.

Francia Pietro, Adduci Carmen, Palano Francesca, Semprini Lorenzo, Serdoz Andrea, Montesanti Dalma, Santini Daria, Musumeci Beatrice, Salvati Adriano, Volpe Massimo, Autore Camillo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

High-risk hypertrophic cardiomyopathy (HCM) patients benefit from the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) may provide comparable protection while avoiding the shortcomings of transvenous (TV) leads. We assessed S-ICD eligibility according to surface ECG screening test in a cohort of high-risk HCM patients.

METHODS AND

RESULTS

47 HCM patients (3 S-ICD candidates; 41 TV-ICD patients without pacing indication; and 3 pacemaker-dependent TV-ICD patients) underwent 4 screening protocols: standard (n = 44); exercise (n = 33); continuous pacing (n = 44); alternating paced/spontaneous QRS (n = 41). Of the 44 patients in the standard screening group, 41 (93%) were eligible. Max LV thickness was inversely related to the number of qualifying leads (3 leads: 21 ± 4 mm; 2 leads: 22 ± 6 mm; 1 lead: 25 ± 6 mm; no leads: 28 ± 11 mm; P = 0.07). Of the 33 patients in the exercise group, 5 were ineligible (3 after exercise). Of these, 2 became eligible after moving sternal electrodes from the left to the right parasternal line (eligibility rate: 30/33; 91%). Of the 44 patients in the continuous pacing group, 28 (64%) were eligible, 8 of which with right parasternal electrodes. In the paced/spontaneous QRS group (n = 41), 21 patients (51%) had at least 1 eligible lead during pacing and retained compatibility on the same lead during spontaneous rhythm, 5 of which with right parasternal electrodes.

CONCLUSIONS

S-ICD screening failure is low in HCM, provided that patients with severe hypertrophy are carefully evaluated. Exercise test should be performed and right parasternal leads tested. Pacemaker patients display lower eligibility rate.

Для цитирования: Francia Pietro, Adduci Carmen, Palano Francesca, Semprini Lorenzo, Serdoz Andrea, Montesanti Dalma, Santini Daria, Musumeci Beatrice, Salvati Adriano, Volpe Massimo, Autore Camillo. Eligibility for the Subcutaneous Implantable Cardioverter-Defibrillator in Patients With Hypertrophic Cardiomyopathy.. Journal of cardiovascular electrophysiology. 2015. DOI: 10.1111/jce.12714.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.