MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/jamaophthalmol.2023.1114

Медицинская библиотека · JAMA ophthalmology · 2023

Potential Rare Danger of Presumably Benign Artificial Tears.

Walker Maria K, Berntsen David A, Robich Matt L, Fenton Rachel L, Ticak Anita, Assaad Justina R, Queener Hope M, Chiu Stephanie J, Farsiu Sina, Mutti Donald O, Jones-Jordan Lisa A, Walline Jeffrey J, BLINK Study Group

СтатьяКомментарийПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate changes in subfoveal choroidal thickness and area in children wearing soft multifocal contact lenses (MFCLs) for myopia control.

METHODS

Analyses included 281 myopic children aged 7 to 11 years in the Bifocal Lenses in Nearsighted Kids (BLINK) Study randomly assigned to wear single vision contact lenses (SVCLs), +1.50 D add, or +2.50 D add center-distance MFCL. Subfoveal choroidal thickness and choroidal area were measured using spectral-domain optical coherence tomography before and after 2 weeks of lens wear, and then annually for 3 years. Repeated measures linear regression was used to determine the effect of contact lens wear on the choroid and test the association between choroidal changes and axial elongation.

RESULTS

After initiating contact lens wear, mean ± SE subfoveal choroidal thickness and choroidal area increased in the +2.50 D MFCL group compared with the SVCL group by 8 ± 3 µm (P = 0.003) and 0.07 ± 0.02 mm2 (P = 0.002), a difference maintained throughout the 3-year study (P ≥ 0.55). Increased choroidal thickness and area after 2 weeks in the +2.50 D MFCL group vs. SVCL group were associated with less axial elongation over 3 years (β = -0.0058 mm/µm and -0.947 mm/mm2; P = 0.02 and P = 0.006; 20% and 29% of total treatment effect, respectively).

CONCLUSIONS

The choroid increased in subfoveal thickness and area after 2 weeks of +2.50 D MFCL wear, which was maintained for 3 years and was associated with slower axial elongation. However, only a portion of the treatment effect can be accounted for by the choroidal parameters.

Для цитирования: Walker Maria K, Berntsen David A, Robich Matt L, Fenton Rachel L, Ticak Anita, Assaad Justina R, Queener Hope M, Chiu Stephanie J, Farsiu Sina, Mutti Donald O, Jones-Jordan Lisa A, Walline Jeffrey J, BLINK Study Group. Potential Rare Danger of Presumably Benign Artificial Tears.. JAMA ophthalmology. 2023. DOI: 10.1001/jamaophthalmol.2023.1114.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.