OBJECTIVES

Permanent pacemaker (PPM) implantation is required in 3-8% of all patients undergoing aortic valve replacement (AVR). Our aim was to evaluate long-term PPM dependency and recovery of atrioventricular (AV) conduction disorders during follow-up in these patients.

METHODS

Since January 1997, a total of 2106 consecutive patients underwent isolated AVR at our institution. Of these, 138 patients (6.6%, 72 female, median age 71 (37-89) years) developed significant conduction disorders leading to PPM implantation postoperatively. Preoperative ECG showed normal sinus rhythm (n = 64), first degree AV block (n = 19), left bundle branch block (n = 13), right bundle branch block (n = 16), left anterior hemiblock (n = 14) and AV block with ventricular escape rhythm (n = 10). Atrial fibrillation was present in 23 patients. Pacemakers were implanted after a median of 7 (1-30) days following AVR. PPM dependency was analysed by ECG and pacemaker check during follow-up.

RESULTS

A total of 45 of 138 patients with postoperative PPM Implantation died during a mean follow-up time of 5.3 ± 4.7 years. A further 9 patients were lost to follow-up. Long-term survivals at 1, 5 and 10 years were 88%, 79% and 59%, respectively. Only 8 (10%) of 84 survivors were no longer pacemaker-dependent. The majority of patients (n = 66, 79%) required permanent ventricular stimulation, and the remaining 10 (13%) showed intermittent stimulation with a mean ventricular stimulation fraction of 73% (22-98%).

CONCLUSIONS

The majority of patients do not recover from AV conduction disorders after AVR. Since higher-grade AV blocks expose patients to a high risk of sudden death after surgery, we recommend early implantation of permanent pacemaker.

Для цитирования: Baraki Hassina, Al Ahmad Ammar, Jeng-Singh Stefan, Saito Shunsuke, Schmitto Jan Dieter, Fleischer Bernhard, Haverich Axel, Kutschka Ingo. Pacemaker dependency after isolated aortic valve replacement: do conductance disorders recover over time?. Interactive cardiovascular and thoracic surgery. 2013. DOI: 10.1093/icvts/ivs555.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.