BACKGROUND

The aim of this study was to evaluate the risk of an air embolization with the volume of the insufflation tube during induction of laparoscopy. A further objective was to determine the LD₅₀ of air in young piglets.

METHODS

End-tidal carbon dioxide pressure ([Formula: see text]), pulmonary arterial pressure (P pa), heart rate (f c), and mean arterial pressure (P a carot) were measured in 17 piglets divided into three groups: group 1 (n = 6), bolus application (CO₂ embolization, followed by air embolization, 2 mL/kg each), group 2 (n = 7), continuous air embolization (30 min, 0.2 mL/kg/min), and group 3 (n = 4), continuous CO₂ embolization (30 min, 0.4 mL/kg/min).

RESULTS

All animals survived CO₂ embolism. Air embolization as a bolus (2 mL/kg) or with an accumulated volume of 3.1 mL/kg led to death. Decreases in [Formula: see text] indicated air or massive CO₂ embolization only. There was a good correlation between [Formula: see text] and P pa in case of air embolization (r = -0.80, p < 0.0001). In contrast, no dependency was recognized during CO₂ embolism (r = -0.17, p = 0.2).

CONCLUSIONS

In order to minimize the lethal risk of gas embolization, the insufflation system has to be completely filled with CO₂ before connecting to the patient.

Для цитирования: Richter Steffen, Matthes Christine, Ploenes Till, Aksakal Devrim, Wowra Tobias, Hückstädt Thomas, Schier Felix, Kampmann Christoph. Air in the insufflation tube may cause fatal embolizations in laparoscopic surgery: an animal study.. Surgical endoscopy. 2012. DOI: 10.1007/s00464-012-2651-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.