Аннотация

AIMS: Left ventricular (LV) lead positioning for cardiac resynchronization therapy (CRT) is largely empirical and operator-dependent. Our aim was to determine whether cardiac magnetic resonance (CMR)-guided CRT may improve the acute and the chronic response.

METHODS AND

RESULTS

CMR-derived anatomical models and dyssynchrony maps were created for 20 patients. The CMR targets (three latest activated segments with <50% scar) were overlaid on to live fluoroscopy. Acute haemodynamic response (AHR) to LV pacing was assessed using an intra-ventricular pressure wire. Chronic CRT response (end-systolic volume reduction ≥15%) was assessed 6 months post-implantation. All patients underwent successful CMR-guided LV lead placement. A CMR target segment was paced in 75% of patients. The mean change in LVdP/dtmax for the CMR target was +14.2 ± 12.5 vs. +18.7 ± 11.9% for the best AHR in any segment and +12.0 ± 13.8% for the segment based on coronary sinus (CS) venography. Using CMR guidance, the acute responder rate was 60 vs. 50% on the basis of venography. At 6 months 60% of patients were echocardiographic responders. Of the echocardiographic responders, 92% were successfully paced in a CMR target segment compared with only 50% of non-responders (P = 0.04).

CONCLUSION

CMR guidance compared well when validated against the AHR. Lead placement was possible in the CMR target region in most patients with an AHR comparable with the best achieved in any CS branch. The chronic response was significantly better in patients paced in a CMR target segment. These results suggest that CMR guidance may represent a clinically useful tool for CRT.

Для цитирования: Shetty Anoop K, Duckett Simon G, Ginks Matthew R, Ma Yinglaing, Sohal Manav, Bostock Julian, Kapetanakis Stam, Singh Jagmeet P, Rhode Kawal, Wright Matthew, O'Neill Mark D, Gill Jaswinder S, Carr-White Gerald, Razavi Reza, Rinaldi Christopher Aldo. Cardiac magnetic resonance-derived anatomy, scar, and dyssynchrony fused with fluoroscopy to guide LV lead placement in cardiac resynchronization therapy: a comparison with acute haemodynamic measures and echocardiographic reverse remodelling.. European heart journal. Cardiovascular Imaging. 2012. DOI: 10.1093/ehjci/jes270.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.