MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/iembs.2011.6090315

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2011

The aortic valve dynamics role in the recovery treatments of patients with left ventricular assist devices.

Faragallah George, Wang Yu, Divo Eduardo, Simaan Marwan

СтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

This paper intends to define an optimal range for the pump speed of Rotary Left Ventricular Assist Devices (LVADs) that are used in bridge-to-recovery treatments. If the pump is operating within that optimal range, the aortic valve will be working properly (i.e. opening and closing) in each cardiac cycle. The proper operation of the aortic valve is a very important factor in helping the heart muscle recovers. The optimal range varies depending on the severity of the Heart Failure (HF) and the level of activity of the patient. A comparison is shown between the total flow produced as a result of operating the pump within the optimal range and the physiological demand of the patient. The comparison suggests that for cases of mild to moderate HF the flow produced is close to the physiological demand, but in severe cases the flow is significantly less than what the patient requires. Furthermore, our results suggest that data from the pump flow and the left ventricle volume signals can be used to test whether or not the aortic valve is experiencing permanent closure. Also an investigation of the aortic valve opening duration is presented for two cases: first, for mild HF case with varying Heart Rate (HR) and then for fixed HR and mild to severe HF cases. These Simulation results are obtained using a 6(th) order mathematical model of the cardiovascular-LVAD system.

Для цитирования: Faragallah George, Wang Yu, Divo Eduardo, Simaan Marwan. The aortic valve dynamics role in the recovery treatments of patients with left ventricular assist devices.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2011. DOI: 10.1109/iembs.2011.6090315.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.