A case of a 'lost' nasogastric tube.

Sankar V, Shakeel M, Keh S, Ah-See K W

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To present the case of a 'lost' nasogastric tube and to highlight the importance of imaging and/or chest X-ray after nasogastric tube insertion, especially in unreliable patients.

CASE REPORT: A 50-year-old man, undergoing radiotherapy treatment for squamous cell carcinoma of the tongue base, was admitted for pain control and nasogastric tube feeding. This patient required multiple nasogastric tubes over a two-week period. The patient repeatedly denied pulling the nasogastric tube out and we were unable to establish the exact mode of nasogastric tube removal. On one such occasion another tube was inserted and a check X-ray showed two feeding tubes; the latest one was lying in the left main bronchus and the old nasogastric tube was observed in the oesophagus, with its upper end jutting above the hypopharynx. It was apparent that the patient had somehow cut the tube and swallowed it.

CONCLUSION

This case not only illustrates the importance of flexible nasendoscopy and/or chest X-ray for checking the position of the nasogastric tube, but also highlights that some patients are not tolerant of nasogastric tubes. The use of nasogastric tubes should be avoided in these patients to prevent any self-inflicted injury.

Для цитирования: Sankar V, Shakeel M, Keh S, Ah-See K W. A case of a 'lost' nasogastric tube.. The Journal of laryngology and otology. 2012. DOI: 10.1017/s0022215112002447.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.