MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jce.12701

Медицинская библиотека · Journal of cardiovascular electrophysiology · 2015

Sex Differences in Device Therapies for Ventricular Arrhythmias or Death in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT) Trial.

Tompkins Christine M, Kutyifa Valentina, Arshad Aysha, McNitt Scott, Polonsky Bronislava, Wang Paul J, Moss Arthur J, Zareba Wojciech

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

INTRODUCTION

Studies suggest that women with ischemic heart disease are less likely to experience appropriate ICD therapies for ventricular arrhythmias (VT/VF). We evaluated the influence of sex on arrhythmic events or death in subjects enrolled in MADIT-CRT.

METHODS AND

RESULTS

Arrhythmic event rates, defined as VT/VF treated with defibrillator therapy or all-cause death, were determined among 1,790 subjects enrolled in MADIT-CRT with documented 3-year follow-up. Predictors of VT/VF/death were identified using multivariate analysis. Ninety-one (21%) women and 466 (35%) men experienced VT/VF/death over the follow-up period. The overall probability of VT/VF/death was significantly lower in women versus men (HR 0.62; P < 0.001). The probability of VT/VF/death was the lowest in women with ischemic heart disease (HR 0.51; P = 0.003). In ICD subjects, the 3-year risk of VT/VF was lower in ischemic women versus men (P = 0.021), and in nonischemic women versus men (P = 0.049). The probability of VT/VF/death was significantly lower in women (HR 0.52; P = 0.007) and men (HR 0.74; P = 0.018) with LBBB who received CRT-D. Appropriate shock therapy strongly correlated with increased risk of death during postshock follow-up in women (HR 5.18; P = 0.001) and men (HR 1.63; P = 0.033); interaction P value of 0.034.

CONCLUSION

In this substudy of MADIT-CRT, sex, etiology of heart disease and type of device implanted significantly influenced subsequent risk for VT/VF or death. Women with ischemic heart disease and women with LBBB who received CRT-D had the lowest incidence of VT/VF or death when compared to men. Appropriate shock therapy was a strong predictor of death, particularly in women.

Для цитирования: Tompkins Christine M, Kutyifa Valentina, Arshad Aysha, McNitt Scott, Polonsky Bronislava, Wang Paul J, Moss Arthur J, Zareba Wojciech. Sex Differences in Device Therapies for Ventricular Arrhythmias or Death in the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy (MADIT-CRT) Trial.. Journal of cardiovascular electrophysiology. 2015. DOI: 10.1111/jce.12701.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.